Output temperature of water is regulated by setting the temperature on the front of the remote control.
Safety factors should be considered when selecting the water temperature setting of the water heater’s remote
control. The remote control was set at 110°F before the water heater was shipped from the factory. This is the
recommended starting point.
Water temperatures above 120°F can cause severe burns or death from scalding. The thermostat is adjusted to
its lowest temperature position when shipped from the factory.
Be sure to read and follow the warnings outlined in this manual and on the label located on the water heater.
Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in branch
water lines.
Procedures for adjusting the thermostat for energy efficient operation at the minimum water temperature
setting consistent with the consumer‘s needs.
WATER TEMPERATURE SETTING CONTINUED
Set Temperature Memory
1. This model can memorize and save the last set temperature on the remote control with “priority”.
2. If no remote control has “priority”, the set temperature of the unit will be the same as the set temperature of
the remote control which starts the water heater.
• This water heater contains an electronically controlled thermostat. From the factory, the temperature range is
between 90°F and 140°F.
• The remote control is factory preset to 110°F.
• To turn the remote control ON or OFF, press the POWER button for more than 3 seconds.
• To adjust the temperature to a required setting, in“priority” mode, press the UP or DOWN temperature
button. Press and hold UP or DOWN to raise or lower the temperature continuously.
• When the unit is in use, the set temperature can increase to 122°F, but there is no limit to temperature
decrease. To increase the temperature more than 122°F, the water will need to be shut off first.
NOTICE:
If inlet water temperature is high, and set temperature is low, the actual temperature might be higher
than the set temperature, and vice versa.
• The display will read the set temperature if the water heater is not in use or there is no water flow. If the
water heater is in use or has water flow, the display will read the actual temperature. To view the set
temperature in this condition, press UP or DOWN and the set temperature will flash for 3 seconds.
• The hottest temperature water will be at the hot water faucet closest to the water heater.
• Always remember to test the water temperature with your hand before use and remember that hotter water
increases the risk of scald injury.
• Always supervise young children or others who are incapacitated.
• If the water heater has been subjected to fire, flood or physical damage, turn off the manual gas shut-off
valve(s), and do not operate the water heater again until it has been checked by qualified personnel.
WARNING:
Should overheating occur or the gas supply fail to shut off, turn off the manual gas control
valve to the water heater.
NOTICE:
If the BATH control ls turned on, the temperature setting on the MAIN control cannot be
changed. The BATH control(s) will always have PRIORITY over the MAIN control.