![background image](http://html1.mh-extra.com/html/campbell/skyvue-8m/skyvue-8m_product-manual_489150018.webp)
Signal voltage levels:
Minimum value Nominal value Maximum value
RS-232 communications
RS-232 input threshold low
0.8 V
1.5 V
–
RS-232 input threshold high
–
2.0 V
2.4 V
RS-232 input absolute maximum
–15 V
–
+15 V
RS-232 input resistance
12 KΩ
–
–
RS-232 output voltage low
–
–
0.4 V
RS-232 output voltage high (into 3 KΩ)
4.4 V
–
–
USB Service Port USB1.1 and 2.0 compatible, fixed 115200 baud.
2.4.7 Transport, shock, and vibration certification
When contained within the military transport case from Campbell Scientific (see
(p. 22)), the SkyVUE 8M complies with the following standards:
MIL-STD-810g
DEF STAN 00-035
Further details are available from Campbell Scientific.
2.4.8 Compliance and testing
NOTE:
Further details regarding compliance and testing are available upon request.
EMC compliance:
EN 61326-1:2013
Electrical safety compliance:
EN 61010-1:2010
Laser safety compliance:
EN 60825-1:2014
Eye safety standard:
Class 1M
Vibration:
BS EN 60068-2-6:2008 Test Fc: Vibration (Sinusoidal)
Frequency range:
5 to 150 Hz (exceeds Lloyd's Register test levels)
SkyVUE™8M Tactical LIDAR Ceilometer
13