Appendix D. Replacing the
SkyVUE 8M PSU
The Power Supply Unit (PSU) can be replaced in the SkyVUE 8M as follows:
1. Disconnect the power to the SkyVUE 8M and open the housing.
2. Disconnect all the plugs from the PSU.
3. Use a 3 mm ball-end hexagonal-key to remove the two M4 x 12 socket head screws on the
chassis plate that are on the bent-up tabs on the left and right hand sides.
4. Pull the PSU forward removing the PSU.
5. Loosen the four screws holding the PSU in place and slide off the PSU.
6. Re-insert the new PSU and push back into position.
7. Replace the two screws on the chassis plate.
8. Re-attach the cable plugs into the correct sockets on the new PSU ensuring that each is
connected properly.
9. Ensure that the battery ON/OFF switch is set to OFF.