NL200/201 Network Link Interface
24
FIGURE 8-1. Working around firewalls
8.1.1 Configuring the NL200/201
x
Connect to the NL200/201 in
DevConfig
(see Section
6
,
Configuring the
NL200/201
(p. 10)
).
x
On the NL200 tab:
o
Set
Bridge Mode
to
disable
.
o
Set
Use DHCP
to
disable
.
o
Input the
IP Address
,
Network Mask
, and
Default Gateway
. These
values can be provided by your network administrator.
x
On the Network Services tab:
o
Make note of the
PakBus/TCP Server Port
.
8.1.2 Configuring the Datalogger
The datalogger must first be configured for internet
communication (i.e., through an NL115, an NL120, a second
NL200/201, or a cellular modem).
x
Connect a serial cable from the PC COM port to the datalogger’s RS-232
port.
x
Open
DevConfig
. Select the device type of the datalogger (CR800,
CR1000, or CR3000), the appropriate
Communication Port
, and
Baud
Rate
. Press
Connect
to connect to the datalogger.
x
On the Network Services tab:
o
Under
PakBus TCP Client Connections
, input the NL200/201’s
IP
address
and
PakBus TCP Server Port
.
x
Press
Apply
to save the changes and then close
DevConfig
.
NOTE
LoggerNet
Firewall
Firewall
Firewall
Cellular Network
Internet / WAN
Summary of Contents for NL200
Page 2: ......
Page 3: ......
Page 7: ......
Page 11: ...Table of Contents iv...
Page 39: ...NL200 201 Network Link Interface 28...
Page 45: ...Appendix B Cables Pinouts LED Function and Jumper B 4...
Page 60: ......