NL200/201 Network Link Interface
13
PakBus® address is
t
4000. Hellos from devices with PakBus address
t
4000
are automatically accepted as neighbors.
7.1.1 Physical Setup
Using the supplied serial cable, connect the NL200/201’s CS I/O port or RS-
232 port to the datalogger’s CS I/O or RS-232 port, respectively. The NL201
will be powered if connected via CS I/O. Alternatively, power the NL200 or
NL201 through the barrel-connector jack located on the edge of the device.
Connect the NL200/201 to your network using an Ethernet cable, attaching one
end of the cable to the NL200/201’s Ethernet port and the other end to your
network. Ensure that the device is powered up by inspecting the Power LED.
7.1.2 Configuring the NL200/201
RS-232 PakBus® Router
x
Connect to the NL200/201 in
DevConfig
(see Section
6
,
Configuring the
NL200/201
(p. 10)
).
x
On the NL200 tab:
o
Set
Bridge Mode
to
disable
.
x
On the RS-232 tab:
o
Set
Configuration
to
PakBus
.
o
Set
Baud Rate
to baud rate of attached device.
o
Set
Beacon Interval
,
Verify Interval
, and
PakBus Neighbors
Allowed
as described above. Often the default values can be used.
However, an allowed neighbors list can be useful in restricting
communication paths.
x
On the Network Services tab:
o
Make note of the
PakBus\TCP Server Port
. (The default
PakBus/TCP Server Port
is 6785. Unless firewall issues exist, it is
not necessary to change the port from its default value.)
CS I/O PakBus® Router
x
Connect to the NL200/201 in
DevConfig
(see Section
6
,
Configuring the
NL200/201
(p. 10)
).
x
On the NL200 tab:
o
Set
Bridge Mode
to
disable
.
x
On the CS I/O tab:
o
Set
Configuration
to
PakBus
.