Section 12. Program Control Instructions
12-9
This instruction is not necessary in networks with wireless sensors and only
one Master datalogger, because the Wireless Network Master (P193) and
Wireless Network Remote (P196) instructions perform these functions
automatically.
This instruction can also be used to remove a datalogger from the PakBus
network.
3: PakBus - Send Message (P192)
1: 00 Port
2: 0000 Address
3: 2 Clock Report
Message Type
Entry
Description
2
Clock report; sends the current time.
13
The datalogger that receives this message will remove the sending
datalogger from its neighbor list (and therefore all links to the sending
datalogger).
Wireless Network Master (P193)
A program control instruction that is used to prepare the local datalogger to
send data to or receive data from one or more dataloggers/wireless sensors in a
PakBus network. The instruction also assigns a transmission time to the remote
dataloggers/wireless sensors. Instruction 193 does not actually initiate the
transfer of data. Data transfer is initiated by the wireless sensor.
Multiple Instruction 193s can be used in a program to configure up to four
different groups of dataloggers/wireless sensors. A "group" is determined by
the First Remote Address and the Number of Remotes. A datalogger/wireless
sensor can only belong to one group. An error message will occur (E81) if a
datalogger/wireless sensor is assigned to more than one group.
4: PakBus - Wireless Network Master (P193)
1: 00 Number of Remotes
2: 0000 First Remote Address
3: 0000 Time Into Transmit Interval (sec)
4: 0000 Transmit Interval (sec, 0 = use execution interval)
5: 00 Transmit Delay Between Remotes (sec)
6: 00 Swath to Receive
7: 0000 First Loc for Data Received [ ______________ ]
8: 00 Swath to Send
9: 0000 First Loc to Send [ ______________ ]
10: 0000 Result Code Loc [ ______________ ]
Notes:
The wireless sensors will actually begin transmitting before the specified
transmission time (based on Time Into Transmit Interval and Transmit Interval)
so that transmission is complete when the specified transmission time occurs.
The Transmit Delay Between Remotes is factored into to the transmit time
assigned to each remote.
Summary of Contents for CR510
Page 2: ...This is a blank page ...
Page 4: ...This is a blank page ...
Page 10: ...This is a blank page ...
Page 44: ...SECTION 1 FUNCTIONAL MODES 1 14 This is a blank page ...
Page 56: ...SECTION 3 INSTRUCTION SET BASICS 3 8 ...
Page 104: ...SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES 8 8 This is a blank page ...
Page 128: ...SECTION 10 PROCESSING INSTRUCTIONS 10 8 This is a blank page ...
Page 144: ...SECTION 12 PROGRAM CONTROL INSTRUCTIONS 12 10 This is a blank page ...
Page 172: ...SECTION 14 INSTALLATION AND MAINTENANCE 14 10 This is a blank page ...
Page 176: ...APPENDIX A GLOSSARY A 4 This is a blank page ...
Page 184: ...This is a blank page ...
Page 188: ...APPENDIX D DATALOGGER INITIATED COMMUNICATIONS D 4 This is a blank page ...
Page 196: ...APPENDIX F MODBUS ON THE CR10 X AND CR510 F 4 This is a blank page ...
Page 197: ...APPENDIX G TD OPERATING SYSTEM ADDENDUM FOR CR510 CR10X AND CR23X MANUALS ...
Page 198: ...This is a blank page ...
Page 200: ...This is a blank page ...
Page 206: ...TABLE DATA ADDENDUM AD 6 This is a blank page ...
Page 222: ...TD ADDENDUM SECTION 1 FUNCTIONAL MODES AD 1 8 This is a blank page ...
Page 238: ...TD ADDENDUM SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES AD 8 10 This is a blank page ...
Page 240: ...This is a blank page ...