SECTION 9. INPUT/OUTPUT INSTRUCTIONS
9-11
PARAM.
DATA
NUMBER
TYPE
DESCRIPTION
01:
2
Repetitions Hit C (--) to
skip repeat of
excitation
02:
2
Single-ended channel
for first measurement
03:
2
Excitation Channel
04:
2
Start frequency of
sweep (100'S of Hz)
05:
2
End frequency of
sweep (100'S of Hz)
06:
4
# Cycles to measure (0
means none)
07:
4
Delay before excitation
applied (0.01 sec units)
08:
4
Input location (1/T
2
), T
in ms
09:
FP
Multiplier
10:
FP
Offset
Input locations altered: 1 per repetition
*** 29 INW PS9105E ***
FUNCTION
The Instrumentation Northwest PS9105
Enhanced Pressure Transducer is used to
measure water level. This instruction excites
the PS9105 with a single excitation channel and
measures the sensor’s output on two
consecutive differential analog input channels.
The pressure and sensor temperature are
written into two consecutive input locations
starting at the location specified in parameter 3.
Each PS9105 has 20 enhanced measurement
parameters that are documented on the
calibration sheet. Enter these parameters into
Instruction 29.
PARAM.
DATA
NUMBER
TYPE
DESCRIPTION
01:
2
Differential channel
number for first
measurement
02:
2
Excitation channel
number
03:
4
Input location number
04:
FP
Pressure Range (psig)
(enh. par. 1)
05:
FP
Enhanced Parameter 2
06:
FP
Enhanced Parameter 3
07:
FP
Enhanced Parameter 4
08:
FP
Enhanced Parameter 5
09:
FP
Enhanced Parameter 6
10:
FP
Enhanced Parameter 7
11:
FP
Enhanced Parameter 8
12:
FP
Enhanced Parameter 9
13:
FP
Enhanced Parameter 10
14:
FP
Enhanced Parameter 11
15:
FP
Enhanced Parameter 12
16:
FP
Enhanced Parameter 13
17:
FP
Enhanced Parameter 14
18:
FP
Enhanced Parameter 15
19:
FP
Enhanced Parameter 16
20:
FP
Enhanced Parameter 17
21:
FP
Enhanced Parameter 18
22:
FP
Enhanced Parameter 19
23:
FP
Enhanced Parameter 20
Input location altered: 2
*** 105 SDI-12 RECORDER ***
NOTE:
Version 1.2 of the SDI-12
specification has been implemented in the
CR10X. Features added in this version are
marked with a dagger (†) and may not be
supported by older SDI-12 sensors.
Instruction 105 allows data to be collected from
SDI-12 sensors. The sensor’s SDI-12 data line
is connected to a control port (C1 or C2). The
SDI-12 ground should be connected to a "G"
terminal on the CR10X wiring panel. SDI-12
power may be connected to 12V.
If multiple SDI-12 sensors are used, up to ten
sensors may be connected to a single control
port, but each sensor must have a unique
address and requires a separate Instruction
105.
PARAM.
DATA
NUMBER
TYPE
DESCRIPTION
01:
4
Address (0-9, †10-
126)
02:
2
Command (Table 9-8)
03:
2
Control Port (C1-C8)
04:
4
Input Loc.
05:
FP
Mult
06:
FP
Offset
Input locations altered: 1-9 (†1-99), depending
on the SDI-12 sensor
Intermediate locations required: 21
Summary of Contents for CR510
Page 2: ...This is a blank page ...
Page 4: ...This is a blank page ...
Page 10: ...This is a blank page ...
Page 44: ...SECTION 1 FUNCTIONAL MODES 1 14 This is a blank page ...
Page 56: ...SECTION 3 INSTRUCTION SET BASICS 3 8 ...
Page 104: ...SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES 8 8 This is a blank page ...
Page 128: ...SECTION 10 PROCESSING INSTRUCTIONS 10 8 This is a blank page ...
Page 144: ...SECTION 12 PROGRAM CONTROL INSTRUCTIONS 12 10 This is a blank page ...
Page 172: ...SECTION 14 INSTALLATION AND MAINTENANCE 14 10 This is a blank page ...
Page 176: ...APPENDIX A GLOSSARY A 4 This is a blank page ...
Page 184: ...This is a blank page ...
Page 188: ...APPENDIX D DATALOGGER INITIATED COMMUNICATIONS D 4 This is a blank page ...
Page 196: ...APPENDIX F MODBUS ON THE CR10 X AND CR510 F 4 This is a blank page ...
Page 197: ...APPENDIX G TD OPERATING SYSTEM ADDENDUM FOR CR510 CR10X AND CR23X MANUALS ...
Page 198: ...This is a blank page ...
Page 200: ...This is a blank page ...
Page 206: ...TABLE DATA ADDENDUM AD 6 This is a blank page ...
Page 222: ...TD ADDENDUM SECTION 1 FUNCTIONAL MODES AD 1 8 This is a blank page ...
Page 238: ...TD ADDENDUM SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES AD 8 10 This is a blank page ...
Page 240: ...This is a blank page ...