background image

General Safety 

(continued)

22. Drain tanks of moisture after each 

day’s use. If unit will not be used 
for a while, it is best to leave drain 
cock open until such time as it is to 
be used. This will allow moisture 
to completely drain out and help 
prevent corrosion of inside of tank.

23. Inspect tank yearly for rust, pin holes 

or any other imperfections that 
could cause it to become unsafe. 
NEVER weld or drill holes in air tank.

24. Household use only.
25. To reduce the risk of electrical shock, 

do not expose to rain. Store indoors.

 

Never attempt to 

  repair or modify 

a tank! Welding, drilling or any other 
modification will weaken the tank resulting 
in damage from rupture or explosion. 
Always replace worn or damaged tanks.

 

Drain liquid from  

  tank daily.

SpraYinG precaUtionS

 

Do not spray  

  flammable materials 

in vicinity of open flame or near ignition 
sources including the compressor unit.

 1.  Spray in a well ventilated area, to 

keep fumes from collecting and 
causing health and fire hazards.

 2.  Do not spray in vicinity of open 

flames or other places where a spark 
can cause ignition. Do not smoke 
when spraying paint, insecticides, or 
other flammable substances.

 3.  Use a respirator when spraying.
 4.  Do not direct paint or other sprayed 

material at the compressor. Locate 
compressor as far away from 
the spraying area as possible to 
minimize overspray accumulation on 
the compressor.

 5.  When spraying or cleaning with 

solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer.

 6.  Do not smoke when spraying paint, 

insecticides, or other flammable 
substances.

 7.  Use a face mask/ 

respirator when  
spraying and spray in a 
well ventilated area to 
prevent health and fire hazards.

 8.  Do not direct airstream at body.

assembly

aSSeMblY toolS reqUireD

Tools (not provided) for assembly:
-  (1) #2 Phillips screwdriver
-  (2) adjustable wrenches

wheel aSSeMblY (FiGUre 1)

Wheel assembly kit includes:
-  (2) wheels
-  (2) axle bolts
-  (2) wheel inserts
-   (2) washers
-  (2) nuts
 1.  Wheel has an offset hub. With 

offset hub facing axle iron, 
assemble axle bolt through wheel 
insert, holes in wheel and axle iron.

 2.  Place adjustable wrench on axle 

bolt. Using a second adjustable 
wrench, tighten nut securely to 
threaded part of axle bolt.

 3.  Repeat procedure with other side.

hanDle aSSeMblY (FiGUre 2)

 

Never use the  

  handle to lift the 

unit completely off the ground. Only 
use the handle to lift one end so the 
wheels may be used to move the unit.

Handle assembly kit includes:
-  (1) handle
-  (4) bolts
 1.  Insert ends of handle into tube 

shaped brackets on tank.

 2.  Align screw holes.
 3.  Thread screw into hole until tight.
 4.  Tighten securely with #2 Phillips 

screwdriver.

3

hG3000 Series, hJ3001 Series, hJ3002 Series

www.chpower.com

Figure 2 - handle assembly

Bolt

Handle

Bolt

Figure 1 -  wheel assembly

Wheel

Nut

Bolt

Washer

Wheel insert

Summary of Contents for HJ3001 Series

Page 1: ...s compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suit...

Page 2: ...ay allow it to turn on inadvertently To prevent this and possible damage from power surge turn to OFF position after each use 8 Release all pressures within system slowly dust and debris may be harmfu...

Page 3: ...the spraying area as possible to minimize overspray accumulation on the compressor 5 When spraying or cleaning with solvents or toxic chemicals follow the instructions provided by the chemical manufac...

Page 4: ...essor is running indicating compressor is building pressure properly This gauge will show maximum pressure of compressor when it shuts off automatically at the pressure switch Drain Valve This valve i...

Page 5: ...hether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the proper outlet installed by a qualified technician This product is for use on a nominal 12...

Page 6: ...alve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached see Operating Proc...

Page 7: ...en compressor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution and tighten 2 Loose drain lock 2 Tighten 3 Check valve leaking 3 Disassemble check...

Page 8: ...sure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches air governors and safety valves modified...

Page 9: ...pas quip pour et ne devrait pas tre utilis comme soi pour fournir de l air respirable Pour les applications d air pour la consommation humaine il est n cessaire d quiper le compresseur d air pompe av...

Page 10: ...out signe de faiblesse ou d usure et assurer que tous les raccordements sont s rs ne pas utiliser si endommag Contacter un centre de service autoris pour l inspection ou la r paration Ne Pas faire fon...

Page 11: ...s inflammables 3 Utiliser un respirateur pendant la pulv risation 4 Ne pas diriger la peinture ou autre mat riel pulv ris vers le compresseur Situer le compresseur aussi loin que possible de l endroit...

Page 12: ...r servoir pendant le fonctionnement du compresseur ce qui confirme que le compresseur est en train d augmenter la pression de mani re appropri e Ce manom tre indique la pression maximum du compresseu...

Page 13: ...ant vert l ext rieur avec ou sans rayures jaunes est le fil de terre Ne pas utiliser d adaptateur de mise la terre avec ce produit Ne jamais connecter le fil vert ou vert et jaune une borne lectris Co...

Page 14: ...pression de sortie d passant la pression maximale indiqu e de l accessoire Cycle marche arr t du compresseur En position ON marche le compresseur pompe de l air dans le r servoir Lorsqu il atteint un...

Page 15: ...oteur du r servoir des canalisations d air et des ailettes de refroidissement de la pompe REMARQUE Il faut v rifier et nettoyer p riodiquement le filtre air dans le bo tier du filtre du c t de la t te...

Page 16: ...ibre dans la section de Installation 3 Clapet ou d chargeur d fectueux 3 Remplacer ou r parer Le protecteur de surcharge thermique se d clenche souvant 1 Tension basse 1 V rifier avec un voltm tre 2 F...

Page 17: ...17 Fr S rie HG3000 S rie HJ3001 S rie HJ3002 Notes...

Page 18: ...tallation de fils incorrecte g Autres articles pas indiqu s mais consid r s pi ces fatigue g n rales h Manostats r gulateurs d air et soupapes de s ret qui ont t s modifi s d apr s les r glages de l u...

Page 19: ...e compra con fecha para fines de la garant a Adj ntela a este manual o arch vela en lugar seguro IN634100AV 7 10 2010 Campbell Hausfeld Scott Fetzer Compresores de Aire Port tiles ASME de 13 79 bar Po...

Page 20: ...ver si est n deterioradas o hay fugas Antes de usarlo cerci rese de que las conecciones est n bien apretadas y no lo use si encuentra irregularidades Notif quele a un centro de servicio autorizado par...

Reviews: