background image

Limited Warranty

1.  DURATION: From the date of purchase by the original purchaser as follows: One Year.
2.  WHO GIVES THIS WARRANTY (WARRANTOR): 
  Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400.
3.  WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld 

compressor.

4.  WHAT PRODUCT IS COVERED BY THIS WARRANTY: This Campbell Hausfeld air compressor. 
5.  WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects due to material and workmanship with the exceptions noted below. 
6.  WHAT IS NOT COVERED UNDER THIS WARRANTY:

A.  Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM THE DATE OF 

ORIGINAL PURCHASE AS STATED IN THE DURATION. If this compressor is used for commercial, industrial or rental purposes, the warranty 
will apply for ninety (90) days from the date of purchase. Some States do not allow limitations on how long an implied warranty lasts, so 
the above limitations may not apply to you.

B.  ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE, 

OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or 
consequential damages, so the above limitation or exclusion may not apply to you.

C.  Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with instructions 

provided in the owner’s manual(s) supplied with compressor.

D.  Pre-delivery service, e.g. assembly, oil or lubricants, and adjustment.
E.  Items or service that are normally required to maintain the product, e.g. lubricants, filters and gaskets, etc.
F.  Gasoline engines and components are expressly excluded from coverage under this limited warranty. The Purchaser must comply with 

the warranty given by the engine manufacturer which is supplied with the product.

G.  Additional items not covered under this warranty:

1.  All Compressors

a.  Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance 

with installation and operation guidelines or damaged by contact with tools or surroundings.

b.  Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants. 
c.  Cosmetic defects that do not interfere with compressor functionality.
d.  Electric motors, check valves and pressure switches.
e.  Drain cocks.
f.  Damage due to incorrect voltage or improper wiring.
g.  Other items not listed but considered general wear parts.
h.  Pressure switches, air governors and safety valves modified from factory settings.

2.  Lubricated Compressors

a.  Pump wear or valve damage caused by using oil not specified.
b.  Pump wear or valve damage caused by any oil contamination or by failure to follow proper oil maintenance guidelines.

3.  Belt Drive / Direct Drive / Gas Driven Compressors

a.  Belts.
b.  Ring wear or valve damage from inadequate filter maintenance.
c.  Manually adjusted load/unload and throttle control devices.

7.  ADDITIONAL WARRANTY LIMITATIONS FOR UNITS WITH THE 10 YEAR "TOUGH TANK" GUARANTEE.

A.  WHAT IS COVERED BY THE 10 YEAR "TOUGH TANK" GUARANTEE:

1.  At the warrantor’s option, replace any tank or product which is found to have a manufacturer’s defect in the tank for ten (10) years 

from the date of purchase by the original purchaser and subject to the exclusions below.

B.  WHAT IS  NOT COVERED BY THE 10 YEAR "TOUGH TANK" GUARANTEE:

1.  The compressor and all parts other than the tank, consult the written warranty issued for your specific compressor model.
2.  Defects in the tank not related to a manufacture's defect including but not limited to:

a.  Failures due to rust.
b.  Failures due to corrosive environments.
c.  Failures due to neglect or abuse.

3.  Any tank that has been altered in any way.
4.  Any tank used for anything other than its original intended purpose.
5.  Any unit that has been fitted with any non-OEM parts.
6.  Labor to replace a defective tank.

8  RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, compressor or component which is 

defective, has malfunctioned and/or failed to conform within the duration of the specific warranty period. 

9.  RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:

A.  Provide dated proof of purchase and maintenance records.
B.  Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service Center. Freight 

costs, if any, must be borne by the purchaser.

C.  Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s). 

10. WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and 

serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts. 

This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have other rights which 
vary from State to State or country to country.

8

Operating Instructions

www.chpower.com

Summary of Contents for HJ3001 Series

Page 1: ...s compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suit...

Page 2: ...ay allow it to turn on inadvertently To prevent this and possible damage from power surge turn to OFF position after each use 8 Release all pressures within system slowly dust and debris may be harmfu...

Page 3: ...the spraying area as possible to minimize overspray accumulation on the compressor 5 When spraying or cleaning with solvents or toxic chemicals follow the instructions provided by the chemical manufac...

Page 4: ...essor is running indicating compressor is building pressure properly This gauge will show maximum pressure of compressor when it shuts off automatically at the pressure switch Drain Valve This valve i...

Page 5: ...hether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the proper outlet installed by a qualified technician This product is for use on a nominal 12...

Page 6: ...alve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached see Operating Proc...

Page 7: ...en compressor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution and tighten 2 Loose drain lock 2 Tighten 3 Check valve leaking 3 Disassemble check...

Page 8: ...sure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches air governors and safety valves modified...

Page 9: ...pas quip pour et ne devrait pas tre utilis comme soi pour fournir de l air respirable Pour les applications d air pour la consommation humaine il est n cessaire d quiper le compresseur d air pompe av...

Page 10: ...out signe de faiblesse ou d usure et assurer que tous les raccordements sont s rs ne pas utiliser si endommag Contacter un centre de service autoris pour l inspection ou la r paration Ne Pas faire fon...

Page 11: ...s inflammables 3 Utiliser un respirateur pendant la pulv risation 4 Ne pas diriger la peinture ou autre mat riel pulv ris vers le compresseur Situer le compresseur aussi loin que possible de l endroit...

Page 12: ...r servoir pendant le fonctionnement du compresseur ce qui confirme que le compresseur est en train d augmenter la pression de mani re appropri e Ce manom tre indique la pression maximum du compresseu...

Page 13: ...ant vert l ext rieur avec ou sans rayures jaunes est le fil de terre Ne pas utiliser d adaptateur de mise la terre avec ce produit Ne jamais connecter le fil vert ou vert et jaune une borne lectris Co...

Page 14: ...pression de sortie d passant la pression maximale indiqu e de l accessoire Cycle marche arr t du compresseur En position ON marche le compresseur pompe de l air dans le r servoir Lorsqu il atteint un...

Page 15: ...oteur du r servoir des canalisations d air et des ailettes de refroidissement de la pompe REMARQUE Il faut v rifier et nettoyer p riodiquement le filtre air dans le bo tier du filtre du c t de la t te...

Page 16: ...ibre dans la section de Installation 3 Clapet ou d chargeur d fectueux 3 Remplacer ou r parer Le protecteur de surcharge thermique se d clenche souvant 1 Tension basse 1 V rifier avec un voltm tre 2 F...

Page 17: ...17 Fr S rie HG3000 S rie HJ3001 S rie HJ3002 Notes...

Page 18: ...tallation de fils incorrecte g Autres articles pas indiqu s mais consid r s pi ces fatigue g n rales h Manostats r gulateurs d air et soupapes de s ret qui ont t s modifi s d apr s les r glages de l u...

Page 19: ...e compra con fecha para fines de la garant a Adj ntela a este manual o arch vela en lugar seguro IN634100AV 7 10 2010 Campbell Hausfeld Scott Fetzer Compresores de Aire Port tiles ASME de 13 79 bar Po...

Page 20: ...ver si est n deterioradas o hay fugas Antes de usarlo cerci rese de que las conecciones est n bien apretadas y no lo use si encuentra irregularidades Notif quele a un centro de servicio autorizado par...

Reviews: