background image

3

Operating Instructions

Alternator field is not energized

Low output voltage with no load

High output voltage with no load

Low output voltage under load

Erratic output voltage

Noisy operation

1. Engine speed is too slow
2. Open, shorted, or incorrect wiring

3. Faulty capacitor
4. Open or shorted field windings

5. Open diodes

1. Engine speed is too slow
2. Open diodes
3. Faulty capacitor
4. Open or shorted field windings

1. Faulty capacitor
2. Engine speed is too fast

1. Open diode
2. Engine speed too slow at full load
3. Excessive load applied

1. Unbalanced  engine
2. Dirty, corroded, or loose wiring

connection

3. Unstable load applied

1. Loose generator or engine bolt
2. Short circuit in generator field or load

3. Faulty bearing

1. Adjust engine speed 

2. Referring to the wiring diagram, clean

and reconnect all wiring 

3. Replace capacitor 

4. Test winding resistance, replace field

winding if necessary 

5. Test diodes, replace if necessary 

1. Adjust engine speed 

2. Test diodes, replace if necessary 

3. Replace capacitor 

4. Test winding resistance, replace field

winding if necessary 

1. Replace capacitor 

2. Adjust engine speed 

1. Test diodes, replace if necessary 

2. Adjust engine speed 

3. Reduce the applied load

1. Refer to engine manual
2. Referring to the wiring diagram, clean

and reconnect all wiring 

3. Remove all loads, then apply each one

individually to determine which one is
causing erratic function

1. Tighten all mountings
2. Test winding resistance, replace field

winding if necessary

Test load devices for shorts. Replace
defective load device.

3. Replace bearing

These diagnostic and repair procedures should be performed by an authorized service center.

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Fig. 4 - Wiring Diagram for GN2560V and GN2563V

GN2560V, GN2563V, GN3560V and GN3565V

Rotor

Stator

Ground

Main Winding
120V

Excitation
Winding

Capacitor

Plug

Circuit Breaker

120V Duplex Receptacle
NEMA 5-15R

1

2

3

4

Main Winding
120V

G

W

BK

BK

W

Summary of Contents for GN2560V

Page 1: ...these units are contained in a separate manual Retain all manuals for future reference 2 Never use this generator for any application other than that specified by the manufacturer Never operate this g...

Page 2: ...evel everytime you start your generator Refer to the Engine Manual for SAE API and fill quantity specifications 2 Use of a Ground Fault Circuit Interrupter GFCI is strongly recommended Ground Fault Ci...

Page 3: ...ing if necessary 5 Test diodes replace if necessary 1 Adjust engine speed 2 Test diodes replace if necessary 3 Replace capacitor 4 Test winding resistance replace field winding if necessary 1 Replace...

Page 4: ...embly oil or lubricants and adjustment E Items or service that are normally required to maintain the product i e lubricants and filters F Gasoline engine components are expressly excluded from coverag...

Page 5: ...t et ou en blessures personnelles graves Les instructions du moteur pour ces mod les sont dans un manuel s par Conserver tous les manuels comme r f rence 2 Ne jamais utiliser cette g n ratrice pour un...

Page 6: ...es pi ces d tach es du moteur 6 Fr Instructions D Utilisation Fonctionnement AVANT LE FONCTIONNEMENT 1 V rifier le niveau d huile avant chaque d marrage du moteur Se r f rer au Manuel Du Moteur pour S...

Page 7: ...acer si n cessaire 1 R gler la vitesse du moteur 2 Faire l essai des diodes remplacer si n cessaire 3 Remplacer le condensateur 4 Faire l essai de la r sistance du bobinage et remplacer le bobinage d...

Page 8: ...ONNEMENT DU PRODUIT CAMPBELL HAUSFELD Quelques Provinces tats n autorisent pas l exclusion ni la limitation des dommages fortuits ou indirects La limitation ou exclusion pr c dente peut donc ne pas s...

Page 9: ...seguran a pode causar danos ao equipamento e ou les es pessoais s rias As instru es sobre o motor para estas unidades est o contidas num manual separado Guarde todos os manuais para futura refer ncia...

Page 10: ...do motor que acompanha esta unidade para obter instru es quanto manuten o dos componentes do motor 10 Pg Instru es de Opera o Montagem N O NECESS RIO USAR FERRAMENTAS PARA A MONTAGEM Opera o PR OPERA...

Page 11: ...io 1 Ajuste a velocidade do motor 2 Teste os diodos substitua caso necess rio 3 Substitua o capacitor 4 Teste a resist ncia do enrolamento substitua o enrolamento do campo caso necess rio 1 Substitua...

Page 12: ...EITO FALHA OU MAU FUNCIONAMENTO DO PRODUTO DA CAMPBELL HAUSFELD Alguns estados nos Estados Unidos n o permitem a exclus o ou limite de danos incidentais ou resultantes de forma que o limite e exclus o...

Page 13: ...en otro manual Guarde todos los manuales para futuras referencias 2 Nunca use este generador en ninguna aplicaci n que no sea especificada por el fabricante Nunca opere este generador bajo condicione...

Page 14: ...otor cada vez que encienda el generador Vea las especificaciones de tipo de aceite y cantidades necesarias en el Manual del motor 2 Use un cord n el ctrico que tenga un interruptor autom tico en caso...

Page 15: ...o y limpie y conecte todo el alambrado 3 Reemplace el capacitador 4 Pruebe la resistencia de la bobina reemplace la bobina si es necesario 5 Pruebe los diodos reempl celos si es necesario 1 Ajuste la...

Page 16: ...limitaci n de da os incidente o da os consecuentes as que la limitaci n o exclusi n arriba mencionado no se lo aplicar a C Cualquier incidente que resulte de un accidente da o por env o abuso por part...

Reviews: