background image

5

Operating Instructions and Parts Manual

 

FP260200

www.chpower.com

troubleshooting chart

 

Stop using tool immediately if any of the following problems occur. Serious personal injury could occur.  

  Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.

Symptom

Possible Cause(s)

Corrective Action

Compressor will 

not run

1. Switch in OFF position

1. Make sure compressor is plugged in and switch  

  is ON

2. No electrical power at wall outlet

2. Check circuit breaker or fuse at electrical panel.

3. Compressor has reached automatic  

  shut-off pressure

3. Release air from tank until compressor restarts automatically

4. Motor overheated / overworked

4. Switch unit to OFF, wait 30 minutes to cool, turn ON again 
  to resume work. Make sure compressor is run in a clean, 
  well-ventilated area where temperature will not exceed  
  100°F.

5. Loose electrical connection

5. Check all electrical connections

6. ON / OFF switch bad

6. Replace ON / OFF switch

7. Pressure switch bad

7. Replace pressure switch

8. Defective motor

8. Replace pump / motor assembly

Thermal overload 

protector cuts out 

repeatedly

1. Lack of proper ventilation / room  

  temperature too high

1. Move compressor to a clean,well ventilated area where  

  temperature will not exceed 100°F.

2. Excessive air usage, compressor too  

  small

2. Decrease usage or purchase unit with higher air delivery  

  (SCFM)

Tank pressure 

drops when 

compressor shuts 

off

1. Open tank drain valve

1. Close tank drain valve

2. Loose connections (fittings, tubing,  

  air hose, any connections, etc.)

2. Check all connections with soap and water solution. If a leak  

  is detected, tighten. Or remove fitting and apply pipe tape  

  to threads and reassemble.

 

Do not disassemble check valve with air in  

  tank, bleed tank first.

3. Tank leaks

3. Check entire tank for leaks with soap and water solution.

Compressor runs 

continuously / air 

output lower than 

normal

1. Excessive air usage, compressor  

  too small

1. Decrease usage or purchase unit with higher air delivery  

  (SCFM)

2. Open tank drain valve

2. Close tank drain valve

3. Loose connections (fittings, tubing, 

 air hose, any connections, etc.)

3. Check all connections with soap and water solution. If a leak  

  is detected, tighten. Or remove fitting and apply pipe tape  

  to threads and reassemble.

4. Pump wore out

4. Replace pump / motor assembly

Excessive moisture 

in discharge air

1. Excessive water in tank

1. Drain tank, tilt tank to remove moisture

2. High humidity

2. Move to area of less humidity; use air line filter

Safety valve pops 

open

1. Defective pressure switch

1. Replace pressure switch

2. Defective safety valve

2. Replace safety valve with genuine replacement part

MOIStUre In cOMPreSSeD aIr

Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when 
a compressor is in continuous use for an extended period of time, this moisture will collect in the tank. When using a paint 
spray or sandblast gun, this water will be carried from the tank through the hose, and out of the gun as droplets mixed with 
the spray material.

IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. 
If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective. A filter in the air line (MP3105), 
located as near to the gun as possible, will help eliminate this moisture.

Summary of Contents for FP260200

Page 1: ...lp recognize this information observe the following symbols Danger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potential...

Page 2: ...leaning with solvents or toxic chemicals follow the instructions provided by the chemical manufacturer Hose Precautions 20 Inspect hose before use Do not exceed working pressure marked on hose Do not...

Page 3: ...air pressure released at the hose outlet Turning the regulator knob clockwise to the right will increase air pressure at the outlet Turning the knob counter clockwise to the left will lower air pressu...

Page 4: ...tempting to install service relocate or perform any maintenance Service should be performed by an authorized service representative The compressor should be checked often for any visible problems and...

Page 5: ...ion If a leak is detected tighten Or remove fitting and apply pipe tape to threads and reassemble Do not disassemble check valve with air in tank bleed tank first 3 Tank leaks 3 Check entire tank for...

Page 6: ...ormation Address any correspondence to Model number Campbell Hausfeld Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 450...

Page 7: ...Gauge FP204012AV t 1 24 Regulator and Manifold Assembly FP018800AV t 1 25 ASME Safety Valve V 215100AV 1 26 Check Valve Assembly FP209532AV 1 27 Check Valve 1 28 Poppet 1 29 Spring 1 30 Pressure Switc...

Page 8: ...abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warra...

Page 9: ...e pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation dangereuse imminente qui M NERA la mort ou des blessures...

Page 10: ...iriger la peinture ou autre mat riel pulv ris vers le compresseur Situer le compresseur aussi loin que possible de l endroit de pulv risation pour r duire l accumulation de surpulv risation sur le com...

Page 11: ...la terre Dans l venement d un court circuit la mise la terre diminue le risque de secousse lectrique en fournissant un fil d chappement pour le courant lectrique Ce produit est quip avec un cordon qui...

Page 12: ...7 Quand on a termin d utiliser le compresseur tourner l interrupteur la position OFF ARR T O d brancher le cordon d alimentation et vidanger le r servoir d air Instructions de Maintenance de l Utilis...

Page 13: ...le clapet Avec de l air dans le r servoir purger le r servoir d abord 3 Le r servoir pr sente de pertes 3 V rifier tout le r servoir avec de l eau savonneuse Le compresseur travaille continuelle ment...

Page 14: ...suivante Correspondance Num ro du mod le Campbell Hausfeld Num ro de s rie si applicable Attn Customer Service Description de la pi ce et son num ro sur la liste de pi ces 100 Production Drive Harris...

Page 15: ...lecteur assemblage FP018800AV t 1 25 Soupape de s ret ASME V 215100AV 1 26 Assemblage du clapet FP209532AV 1 27 Clapet 1 28 Champignon 1 29 Ressort 1 30 Pressostat FP018400AV 1 31 R servoir 1 32 Robin...

Page 16: ...de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appareils de s ret sont enlev s ou modifi s la garantie...

Page 17: ...edida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los siguientes s mbolos Peligro indica una situaci n inminentemente peligrosa que si no se evita dar como resultado la muerte o...

Page 18: ...lventes o qu micos t xicos siga las instrucciones del fabricante de dichos qu micos Precauciones para las mangueras 20 Revise la manguera antes del uso No exceda la presi n de trabajo indicada en la m...

Page 19: ...sor El interruptor debe colocarse en la posici n OFF O para conectar o desconectar el cord n el ctrico del tomacorrientes o para cambiar herramientas Interruptor de presi n ubicado internamente Al enc...

Page 20: ...conecte el cord n el ctrico del tomacorrientes y libere toda la presi n del sistema antes de tratar de instalar darle servicio cambiar de lugar o darle cualquier tipo de mantenimiento El servicio debe...

Page 21: ...soluci n de agua y jab n Si se detecta una fuga apriete O quite la conexi n y aplique cinta para tuber as a las rocas y vuelva a armar No desarme la v lvula de retenci n Si hay aire en el tanque prim...

Page 22: ...ente informaci n Puede escribirnos a N mero del modelo Campbell Hausfeld N mero de Serie de haberlo Attn Customer Service Descripci n y n mero del repuesto seg n la lista de repuestos 100 Production D...

Page 23: ...t 1 24 Regulador y ensamble del distribuidor FP018800AV t 1 25 V lvula de seguridad ASME V 215100AV 1 26 Ensamblaje de V lvula de chequeo FP209532AV 1 27 V lvula de chequeo 1 28 Castillete 1 29 Resor...

Page 24: ...cluir la desconexi n o modificaci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a cancelada D Los ajustes normales explicados en el los ma...

Reviews: