background image

0623 IH-10916VND

H-10916

18

Reminder:  Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

LIMITED WARRANTY

 1.

DURATION: From the date of purchase by the original purchaser as follows: One Year.

2.

WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld a Marmon/Berkshire Hathaway Company, 100 Production Drive, Harrison,
Ohio, 45030, Visit www.campbellhausfeld.com

3.

WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld
compressor.

4.

WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: This DC080500 Campbell Hausfeld air compressor.

5.

WHAT IS COVERED UNDER THIS WARRANTY: Parts and Labor to remedy substantial defects due to material and workmanship during the
first year of ownership with the exceptions noted below. Parts only to remedy substantial defects due to material and workmanship during
remaining term of coverage with exceptions noted below.

6.

WHAT IS NOT COVERED UNDER THIS WARRANTY:
A.  Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM THE DATE OF 

ORIGINAL PURCHASE AS STATED IN THE DURATION. If the compressor is used for commercial, industrial or rental purposes, the warranty 
will apply for ninety (90) days from the date of purchase. Two-stage compressors are not limited to a ninety (90) day warranty when 
used in commercial or industrial applications. Some States do not allow limitations on how long an implied warranty lasts, so the above 
limitations may not apply to you

B.  ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE, 

OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or 
consequential damages, so the above limitation or exclusion may not apply to you.

C.  Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with instructions 

provided in the owner’s manual(s) supplied with compressor.

D.  Pre-delivery service, e.g. assembly, oil or lubricants, and adjustment.
E.  Items or service that is normally required to maintain the product, e.g. lubricants, filters and gaskets, etc.
F. 

Gasoline engines and components are expressly excluded from coverage under this limited warranty. The Purchaser must comply with 
the warranty given by the engine manufacturer which is supplied with the product

G.  Additional items not covered under this warranty:

1.

Excluded items pertaining to All Compressors
a.

Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in
accordance with installation and operation guidelines or damaged by contact with tools or surroundings.

b.

Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants.

c.

Cosmetic defects that do not interfere with compressor functionality.

d.

Rusted tanks, including but not limited to rust due to improper drainage or corrosive environments.

e.

The following components are considered normal wear items and are not covered after the first year of ownership. Electric
motor, check valve, pressure switch, regulator, pressure gauges, hose, tubing, pipe, fittings and couplers, screws, nuts,
hardware items, belts, pulleys, flywheel, air filter and housing, gaskets, seals, oil leaks, air leaks, oil consumption or usage,
piston rings.

f.

Tank drain valves.

g.

Damage due to incorrect voltage or improper wiring.

h.

Other items not listed but considered general wear parts.

i.

Pressure switches, air governors, load/unload devices, throttle control devices and safety valves modified from factory
settings.

j.

Damage from inadequate filter maintenance.

k.

Induction motors operated with electricity produced by a generator.

2.

Excluded items specific to Lubricated Compressors:
a.

Pump wear or valve damage caused by using oil not specified.

b.

Pump wear or damage caused by any oil contamination.

c.

Pump wear or damage caused by failure to follow proper oil maintenance guidelines, operation below proper oil level or
operation without oil.

H.  Labor, service call, or transportation charges after the first year of ownership.

7.

RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, compressor or component which is
defective, has malfunctioned and/or failed to conform within the duration of the specific warranty period.

8.

RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
A.  Provide dated proof of purchase and maintenance records.
B.  Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the purchaser.
C.  Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s). 
D.  Repairs requiring overtime, weekend rates, or anything beyond the standard manufacturer warranty repair labor reimbursement rate.
E.  Time required for any security checks, safety training, or similar for service personnel to gain access to facility.
F. 

Location of unit must have adequate clearance for service personnel to perform repairs and easily accessible.

9.

WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and
serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts.

This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have other rights which vary 
from State to State or country to country.

Compresor silencioso de 8 galones

Manual de Instrucciones y Lista de Piezas

IN641800AV   5/16

© 2016 Campbell Hausfeld
A Marmon/Berkshire Hathaway Company

Modelo: DC080500

SP

Summary of Contents for DC080500

Page 1: ...0623 IH 10916VND H 10916 8 Gallon Quiet Compressor Operating Instructions and Parts Manual Model DC080500 IN641800AV 5 16 2016 Campbell Hausfeld A Marmon Berkshire Hathaway Company EN...

Page 2: ...by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference REMINDER Keep your dated proof...

Page 3: ...anual please visit www campbellhausfeld com This is the safety alert symbol It is used to alert you to potential personal injury hazards The meaning of this safety alert symbol is as follows Attention...

Page 4: ...sed material pump spray guns filters lubricators hoses etc make up a high pressure pumping system the following safety precautions must be observed at all times 1 Read all manuals included with this p...

Page 5: ...e tank Make sure to drain tank regularly and inspect periodically for unsafe conditions such as rust formation and corrosion 15 Fast moving air will stir up dust and debris which may be harmful Releas...

Page 6: ...SPECIFICATIONS DC080500 Motor HP 1 0 Tank Capacity 8 gallon Phase Single Number of Cylinders 2 Air Delivery 90 psi 2 4 SCFM Voltage 110 120 Amperes 7 Hertz Cycles 60 Maximum Pressure 125 psi RPM 1750...

Page 7: ...ectrical line with the proper amps If other appliances operate on the same line they will reduce the available amps If the amperage is not adequate the result will be blown fuses or tripped circuits V...

Page 8: ...s ZERO by adjusting regulator knob fully counterclockwise before changing air tools or disconnecting air hose from outlet Tank Pressure Gauge Will show air pressure in tank while the compressor is run...

Page 9: ...ot fit in the desired outlet have the plug or the outlet replaced by a qualified electrician WARNING Risk of electric shock Improper use of grounding plug can result in a risk of electrical shock Plug...

Page 10: ...tion as the plug 3 The receptacles must be connected to circuits rated to carry at least the voltage and amperages shown 4 NEVER have a receptacle replaced with one of a higher amperage before determi...

Page 11: ...tomatic thermal protector that shuts off the motor if it overheats or has too much current This protector is a trip and hold protector To reset unplug the compressor and allow it to completely cool Th...

Page 12: ...illess type compressor requiring no lubrication End of Operation Storage 1 Turn Auto ON OFF switch to OFF position 2 Unplug power cord from wall outlet and wrap around handle to prevent damage when no...

Page 13: ...ector cuts out repeatedly 1 Low voltage 1 Check with voltmeter 2 Clogged air filter 2 Clean filter see Maintenance section 3 Lack of proper ventilation room temperature too high 3 Move compressor to w...

Page 14: ...0623 IH 10916VND H 10916 NOTES MAINTENANCE REPAIR TROUBLESHOOTING OPERATION ASSEMBLY INSTALLATION SAFETY SPECIFICATIONS GETTING STARTED 13...

Page 15: ...Repair Parts visit www campbellhausfeld com 24 hours a day 365 days a year Please provide following information Model number Serial number if any Part description and number as shown in parts list REP...

Page 16: ...UGE 1 8 NPT 1 5 IN DIA 1 17 CONNECT NPT 1 4 X 48 1 18 PRESSURE SWITCH 1 19 SAFETY VALVE 1 20 PLUG 1 4 NPT 1 21 CONNECT NPT 1 4 X 30 1 22 REGULATOR 1 23 OUTLET GAUGE 1 8 NPT 2 IN DIA 1 24 COUPLER 1 25...

Page 17: ...r Serial number if any Part description and number as shown in parts list REPAIR PARTS ILLUSTRATION FOR SR060510SV MAINTENANCE REPAIR TROUBLESHOOTING OPERATION ASSEMBLY INSTALLATION SAFETY SPECIFICATI...

Page 18: ...CON ROD 2 18 CON ROD SCREW M5 X 20 2 19 CROSSOVER TUBE 2 20 O RING FOR CROSSOVER TUBE 4 21 STATOR 1 22 ROTOR 1 23 BEARING 2 24 FRONT END BELL 1 25 BEARING 2 26 ECCENTRIC 2 27 ECCENTRIC SCREW M8 X 10 2...

Page 19: ...h installation and operation guidelines or damaged by contact with tools or surroundings b Pump or valve failure caused by rain excessive humidity corrosive environments or other contaminants c Cosmet...

Page 20: ...0623 IH 10916VND H 10916 Compresor silencioso de 8 galones Manual de Instrucciones y Lista de Piezas IN641800AV 5 16 2016 Campbell Hausfeld A Marmon Berkshire Hathaway Company Modelo DC080500 SP...

Page 21: ...SECHE Por favor lea y guarde estas instrucciones Lealas cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aqui descrito Protejase usted mismo y a los demas obser...

Page 22: ...Si tiene preguntas o no entiende la informaci n presentada en este manual por favor visite www campbellhausfeld com Este es el s mbolo de alerta de seguridad Se usa para alertarle sobre posibles ries...

Page 23: ...tes utilizados bomba de material pistolas rociadoras filtros lubricantes mangueras etc forman un sistema de bombeo de alta presi n se deben cumplir las siguientes precauciones de seguridad en todo mom...

Page 24: ...ainer r guli rement le r servoir et d en faire une inspection p riodique quant aux conditions non s curitaires comme la formation de rouille et la corrosion 15 Le d placement d air rapide remuera la p...

Page 25: ...ICACIONES DC080500 HP del motor 1 0 Capacidad del tanque 30 28 L Fases Monof sico N mero de cilindros 2 Suministro de aire a 90 psi 68 l min Voltaje 110 120 Amperios 7 Hertz Ciclos 60 Presi n m xima 8...

Page 26: ...n la misma l nea reducir n los amperios disponibles Si el amperaje no es el adecuado har que los fusibles se quemen o que los circuitos se desconecten Voltios o voltaje Una medida de la fuerza de una...

Page 27: ...la perilla del regulador completamente en sentido contrario a las agujas del reloj antes de cambiar las herramientas de aire o desconectar la manguera de aire de la salida Medidor de presi n del tanq...

Page 28: ...sta calificado cambie el enchufe o el tomacorriente ADVERTENCIA Riesgo de descarga el ctrica El uso inapropiado de la clavija de conexi n a tierra puede causar un riesgo de descarga el ctrica El enchu...

Page 29: ...l enchufe 3 Los tomacorrientes deben estar conectados a circuitos con la capacidad nominal de surtir al menos el voltaje y amperaje indicados 4 NUNCA reemplace un tomacorriente con uno de mayor ampera...

Page 30: ...emasiada corriente Este protector es del tipo disparar y sostener Para reiniciarlo desconecte el compresor y permita que se enfr e por completo Esto deber a permitir que la sobrecarga autom tica se re...

Page 31: ...funcionamiento almacenamiento 1 Coloque el interruptor de ENCENDIDO APAGADO autom tico en la posici n de apagado 2 Desconecte el cable de alimentaci n del tomacorriente de la pared y enr llelo alreded...

Page 32: ...evise con un volt metro 2 Filtro de aire obstruido 2 Limpie el filtro vea la secci n de Mantenimiento 3 Falta de ventilaci n adecuada la temperatura de la habitaci n es muy alta 3 Mueva el compresor a...

Page 33: ...0623 IH 10916VND H 10916 MANTENIMIENTO REPARACION IDENTIFICACION DE PROBLEMAS OPERACION MONTAJE INSTALACION SEGURIDAD ESPECIFICACIONES PARA COMENZAR Sp13 NOTAS...

Page 34: ...w campbellhausfeld com 24 horas al d a 365 d as al a o Por favor proporcione la siguiente informaci n N mero de modelo N mero de serie si lo tiene Descripci n de la parte y n mero que le corresponde e...

Page 35: ...IELA 2 18 TORNILLO DE BIELA M5 X 20 2 19 TUBO DE FUSI N 2 20 ANILLO EN FORMA DE O PARA TUBO DE FUSI N 4 21 ESTATOR 1 22 ROTOR 1 23 RODAMIENTO 2 24 CAMPANA TERMINAL FRONTAL 1 25 RODAMIENTO 2 26 EXC NTR...

Page 36: ...llhausfeld com 24 horas al d a 365 d as al a o Por favor proporcione la siguiente informaci n N mero de modelo N mero de serie si lo tiene Descripci n de la parte y n mero que le corresponde en la lis...

Page 37: ...IELA 2 18 TORNILLO DE BIELA M5 X 20 2 19 TUBO DE FUSI N 2 20 ANILLO EN FORMA DE O PARA TUBO DE FUSI N 4 21 ESTATOR 1 22 ROTOR 1 23 RODAMIENTO 2 24 CAMPANA TERMINAL FRONTAL 1 25 RODAMIENTO 2 26 EXC NTR...

Page 38: ...b Falla de la bomba o v lvula causada por la lluvia exceso de humedad ambientes corrosivos u otros contaminantes c Defectos cosm ticos que no interfieran con la funcionalidad del compresor d Tanques o...

Page 39: ...23 IH 10916VND H 10916 e Compresseur silencieux de 30 L 8 gal Instructions d Utilisation et Manual de Pi ces Mod le DC080500 IN641800AV 5 16 2016 Campbell Hausfeld A Marmon Berkshire Hathaway Company...

Page 40: ...com Campbell Hausfeld 100 Production Drive Harrison Ohio 45030 Lire et conserver ces instructions Il faut les lire attentivement avant de commencer assembler installer faire fonctionner ou entretenir...

Page 41: ...ne comprenez pas l information pr sent e dans ce manuel visitez www campbellhausfeld com Ce symbole est une alerte la s curit Il sert vous avertir des dangers potentiels de blessure corporelle La sig...

Page 42: ...cautions de s curit suivantes doivent tre prises en consid ration tout moment 1 Lire attentivement tous les manuels inclus avec ce produit Familiarisez vous avec les commandes et l utilisation approp...

Page 43: ...ainer r guli rement le r servoir et d en faire une inspection p riodique quant aux conditions non s curitaires comme la formation de rouille et la corrosion 15 Le d placement d air rapide remuera la p...

Page 44: ...TECHNIQUES DC080500 Moteur HP 1 0 Capacit du r servoir 30 28 L tape Simple Nombre de cylindres 2 Pouss e d air 90 psi 68 l min Tension 110 120 Amp res 7 Hertz cycles 60 Pression maximale 862 kPa RPM 1...

Page 45: ...nsit appropri e Si d autres appareils fonctionnent sur la m me ligne ils r duiront l intensit disponible Si l intensit n est pas ad quate on causera le d clenchement des fusibles ou des court circuits...

Page 46: ...le bouton du r gulateur compl tement en sens antihoraire avant de changer d outil pneumatique ou de boyau air la sortie Manom tre du r servoir Pr sentera la pression d air dans le r servoir alors qu i...

Page 47: ...de remplacer la fiche ou la prise AVERTISSEMENT Risque de d charge lectrique Une mauvaise utilisation de la fiche de mise la terre peut causer un risque de d charge lectrique La fiche doit tre branch...

Page 48: ...tes avec lesquelles elle peut tre utilis e 2 Assurez vous que le produit est branch une prise ayant la m me configuration que la fiche 3 Les r ceptacles doivent tre branch s sur des circuits jaug s po...

Page 49: ...hement et maintien Pour r initialiser d branchez le compresseur et laissez le se refroidir compl tement Ceci devrait permettre la surcharge automatique de se r initialiser Le protecteur pourrait ne pa...

Page 50: ...sans huile n exigeant aucune lubrification Fin de l utilisation rangement 1 Placez l interrupteur marche arr t automatique OFF 2 D branchez le cordon d alimentation de la prise murale et enroulez le a...

Page 51: ...lenche r p tition 1 Faible tension 1 V rifiez avec un voltm tre 2 Filtre air bouch 2 Nettoyez le filtre voir la section d entretien 3 Manque d une ventilation ad quate temp rature de la pi ce trop lev...

Page 52: ...0623 IH 10916VND H 10916 ENTRETIEN R PARATION D PANNAGE UTILISATION ASSEMBLAGE INSTALLATION S CURIT CARACT RISTIQUES D MARRAGE DE L APPAREIL NOTES Fr13...

Page 53: ...de s rie s il y en a un Description et num ro de pi ce comme indiqu sur la liste des pi ces ILLUSTRATION DES PI CES DE REMPLACEMENT POUR LE DC080500 ENTRETIEN R PARATION D PANNAGE UTILISATION ASSEMBL...

Page 54: ...T 2 20 JOINT TORIQUE DU TUYAU DE RACCORDEMENT 4 21 STATOR 1 22 ROTOR 1 23 ROULEMENT 2 24 FLASQUE AVANT 1 25 ROULEMENT 2 26 EXCENTRIQUE 2 27 VIS EXCENTR E M8 X 10 2 28 VENTILATEUR DE REFROIDISSEMENT GA...

Page 55: ...s il y en a un Description et num ro de pi ce comme indiqu sur la liste des pi ces ENTRETIEN R PARATION D PANNAGE UTILISATION ASSEMBLAGE INSTALLATION S CURIT CARACT RISTIQUES D MARRAGE DE L APPAREIL...

Page 56: ...ACCORD 1 4 X 48 NPT 1 18 MANOSTAT 1 19 SOUPAPE DE S CURIT 1 20 BOUCHON 1 4 NPT 1 21 RACCORD 1 4 X 30 NPT 1 22 R GULATEUR 1 23 MANOM TRE DE SORTIE 1 8 NPT 2 PO DIA 1 24 COUPLEUR 1 25 CROU DE D CHARGE 1...

Page 57: ...ts corrosifs ou autres contaminants c Les d fauts cosm tiques n interf rant pas avec le fonctionnement du compresseur d Les r servoirs rouill s y compris mais non limit s la rouille en raison d un mau...

Reviews: