4.1 Connecting the tool to the air power supply
• Check that the safety catch (5) is engaged.
• Adjust the pressure at 900 kPa (9 bar).
• Check the air filter mesh and housing against the air fitting. Clean it if necessary.
• Connect the supply hose to the fitting (26) having first made sure that the fitting is thoroughly clean. Its inner diam-
eter must be at least 6 mm.
IMPORTANT!
4.2 Assembling the extension pole connection (optional)
•
Read the special maintenance instructions (ch. 6).
WARNING!
Never work on trees or ladders, since it is extremely dangerous.
Before starting any task with the tool, wear protective cloths. Check that all the safety and protection devices
can perfectly work and have been exactly assembled.
4.3 Packing and transport
The tool is packed and carried by the manufacturer to the customer in a carton box. The packaged unit weight is 1 kg,
so it can be easily carried without any special help.
WARNING!
Any transport operations must be carried out in compliance with the current safety rules as to working plac-
es.
5.
USE
5.1 Control devices
To start the shear, keep the safety catch (5) in its forward position while pulling the operating lever (3). To stop the
tool, release the operating lever (3).
5.2 Using the tool
WARNING!
•
Never use the tool without its hand guard (6).
•
Always wear adequate and suitable safety clothing for the work to be carried out. Wear a protective helmet,
avoid loose clothing, ties, necklaces, belts or long hair, if not properly tied, which could get caught in mov-
ing parts.
When holding the tool in your hand, perform the following operations:
a) Carefully put a branch between the blades (4-8), then pull the operating lever (3) and cut the branch.
b) Once the branch has been cut, release the operating lever (3) to open the blades and repeat the operation
a).
5.3
Troubleshooting
FAULT
REMEDY
The shear does not work
• Check the air compressor fpr proper functioning
(read the corresponding documentation).
• Check the air supply (see par. 4.1).
The shear has no power
• Check the air hose for cleanness (see par. 4.1).
• Check the blade pin for overtightness.
• Check the compressor air pressure.
When pulling the operating lever, air comes out
• Check the valve stem seal wear and tear (see par. 6.2.4).
Summary of Contents for VICTORY
Page 2: ...2 26 9 7 6 3 5 8 4 B C 4 8 10 10 A...
Page 3: ...D 11 4 8 E 11 12 27 13 28 F 3 5...
Page 4: ...D 11 8 4 27 12 28 11 4 13 8 E 5 F 3...
Page 5: ...14 17 26 18 19 15 16 22 21 20 17 26 G H I...
Page 6: ...L 23 24 M N 25 20...
Page 7: ...O 30 29 P...
Page 8: ...Italiano 7 English 19 Fran ais 31 Espa ol 43 Deutsch 55 67 T rk e 80...
Page 69: ...Campagnola Srl 1 0 Rev 01 20 10 2014 Pag 67 CAMPAGNOLA S r l CAMPAGNOLA S r l CAMPAGNOLA S r l...
Page 71: ...Campagnola Srl 1 0 Rev 01 20 10 2014 Pag 69 1 1 1 1 2 CAMPAGNOLA S r l 1 3 2006 42 1 4...
Page 73: ...Campagnola Srl 1 0 Rev 01 20 10 2014 Pag 71 Campagnola srl 2 3 v 9 bar 2 4...
Page 80: ...Campagnola Srl 1 0 Rev 01 20 10 2014 Pag 78 7 7 1 a b 7 2 2002 95 2002 96 2003 108...
Page 81: ...Campagnola Srl 1 0 Rev 01 20 10 2014 Pag 79...
Page 94: ...Note...