Chapter 6: Parts List and Order Code
75
Flow Computers
Page:
1 of 2
BASE UNIT:
Communication Connection: External Console Port
1141C
[With Communications] NEMA 4 FRP
Communication Connection: External Console Port
1141L
NEMA 3R Steel Enclosure
Communication Connection: DB9
1141G
[OEM] Surface Mount Chassis
Shaded selections indicate stocked items
1141 Code Example: 1141C
55
30
D2
FL
83
00
2C
IM
R1
00
C2
1
POWER SUPPLY / BATTERY
No Battery (only selection for 1141G)
(60 C assembly)
00
Division 2; 6 / 12 vdc charge controller, Integral to mainboard, (1141C & 1141L)
Battery ready (Battery not included)
30
12 vdc - 29 to 33 Ah battery
(60C assembly)
29
12 vdc - 32 Ah battery
32
12 vdc - 50 Ah battery (1141C only)
(60C assembly)
50
12 vdc - 55 Ah battery (1141C only)
55
6 vdc - 12 Ah battery
61
6 vdc - 33 Ah battery
63
6 vdc - 58 Ah battery (1141C only)
65
6 vdc - 58 Ah battery (1141C only)
(60 C assembly)
66
NOTE:
1a. Ambient temperature is -40 to +40C unless otherwise noted
1b. Larger Enclosure/battery available with special acceptance approval.
2
SOLAR PANEL
Bracket
Cable
Approval
None
None
n/a
00
Adj.
10'
Div 2
10
Adj.
10'
Div 2
20
Adj.
10'
Div 2
30
Vertical
10'
Div 2
50
Vertical
None
Div 2
80
NOTE:
2a. All brackets are for 2" pipe
2b. For non standard solar panels please consult factory
3
DISPLAY
None [applicable to all models]
00
2 lines X 16 character LCD Display
D2
2 lines X 16 character, Backlit LCD Display
B2
4
INPUT OPTIONS (MAIN BOARD)
0
0
2
10 A
1
CL & 12VL
B1
1(2)*
1
4
10 A
CL & 12VL
M1
2(4)*
2
4
10 A Dual
Stage
1, 2
CL & 12V
Stepup
FL
NOTE:
4.1 Mainboard has a backlit capability.
4.2 Mainboard has configuration lock switch (Measurement Canada).
5
PROGRAM
IGas (ISO Gas Calcs)
NFlo 4 (Gas/Liquids- Hourly Data)
NOTE:
For other available programs, see PROGRAM LIST document 1100-1002B.
ADD
RS232
/TTL
2
2
24-Apr-06
Hazardous Location Division 2
30
50
80
Effective:
Charge
Controller
Notes
4.X
Transmitter
Supply
RS232/
485/ TTL
RS232
/TTL
None
10
20
0
1
0
1
59
83
P-PLC
M-Modbus
P4
1141 SCANNER MEASUREMENT RTU
Section:
Discrete
I/O
A02
Serial
Port
Analog
Input
RTD
(Analog)
Input
Pulse
Input
Analog
Output
Watts
Summary of Contents for NUFLO 1141C
Page 1: ...Manual No 30165009 Rev 01 NUFLOTM Scanner 1141 RTU Hardware User Manual ...
Page 28: ...Scanner 1141 Hardware User Manual 28 Figure 3 1 Scanner 1141 main circuit board ...
Page 66: ...Scanner 1141 Hardware User Manual 66 ...
Page 67: ...Chapter 6 Parts List and Order Code 67 Chapter 6 Parts List and Order Code Scanner 1141C ...
Page 68: ...Scanner 1141 Hardware User Manual 68 Scanner 1141L ...
Page 69: ...Chapter 6 Parts List and Order Code 69 Scanner 1141G ...
Page 91: ...Appendix A Specifications 91 Outline Dimensions Scanner 1141C ...
Page 92: ...Scanner 1141 Hardware User Manual 92 Scanner 1141L Front and Side Views ...
Page 94: ...Scanner 1141 Hardware User Manual 94 Scanner 1141G ...
Page 96: ...Scanner 1141 Hardware User Manual 96 Drawing 1 Installation ...
Page 97: ...Appendix B Control Drawings 97 Drawing 2 Power Supply ...
Page 98: ...Scanner 1141 Hardware User Manual 98 Drawing 3 Communications Serial Ports ...
Page 99: ...Appendix B Control Drawings 99 Drawing 4 Status Pulse Inputs Outputs ...
Page 100: ...Scanner 1141 Hardware User Manual 100 Drawing 5 RTD Inputs Analog Inputs Outputs ...
Page 101: ...Appendix B Control Drawings 101 Drawing 6 Analog Outputs ...
Page 102: ...Scanner 1141 Hardware User Manual 102 ...
Page 117: ...117 ...
Page 118: ...118 ...
Page 119: ......
Page 120: ......