Chapter 1: Overview and Specifications
13
The display will shut off automatically after a configurable amount of time (usually about 30
seconds). To “wake-up” the display, press the “wake-up” button.
Scanner Software
ScanWin Lite is a Windows
™
-based software program for monitoring, configuring and
downloading Scanner Measurement RTU data on-site. ScanWin Lite’s “wizards” guide the
operator through the setup of hardware, flow runs, and primary devices as well as the collection
of hardware, system, and flow run data. Reports can be exported and printed from ScanWin.
ScanWin Lite also facilitates the upload and download of configuration settings.
ScanWin Pro, an optional upgrade from ScanWin Lite, combines all of the functionality of
ScanWin Lite with a flow run catalog and a relational database that stores historical information
for off-line review. ScanWin Pro also supports the configuration of advanced control and data
capture functions and various connection methods for remote communication with the Scanner
1141.
Scanner Firmware
The Scanner 1141 supports current NGas, NFLo and IGas firmware. Gas calculations meet both
North American (NGas/NFLo) and international measurement standards (IGas).
All three programs accept signals from orifice or turbine meter inputs and RTD temperature
inputs. Gas composition values can be automatically updated through a gas chromatograph
interface using the RS-232 communications port, or they can be manually entered.
All calculations are performed in SI metric units. The Unit Manager automatically converts other
units as required.
IGas
The international standard (IGas) includes ISO-5167, which supports a variety of differential
pressure meters, venturi and flow nozzles. ISO-T30SC1088 is supported for turbine meter
measurement.
NGas
NGas firmware solves Manual of Petroleum Measurement Standards (MPMS), and American
Gas Association (AGA) (Reports 3 (1992), 5, and 7) calculations including volume, mass, and
energy. The calculation speeds meet or exceed API standards for flow computers. The
supercompressibility calculations performed include:
•
AGA-8 (1992)
•
Redlich-Kwong
•
Standing Katz
Summary of Contents for NUFLO 1141C
Page 1: ...Manual No 30165009 Rev 01 NUFLOTM Scanner 1141 RTU Hardware User Manual ...
Page 28: ...Scanner 1141 Hardware User Manual 28 Figure 3 1 Scanner 1141 main circuit board ...
Page 66: ...Scanner 1141 Hardware User Manual 66 ...
Page 67: ...Chapter 6 Parts List and Order Code 67 Chapter 6 Parts List and Order Code Scanner 1141C ...
Page 68: ...Scanner 1141 Hardware User Manual 68 Scanner 1141L ...
Page 69: ...Chapter 6 Parts List and Order Code 69 Scanner 1141G ...
Page 91: ...Appendix A Specifications 91 Outline Dimensions Scanner 1141C ...
Page 92: ...Scanner 1141 Hardware User Manual 92 Scanner 1141L Front and Side Views ...
Page 94: ...Scanner 1141 Hardware User Manual 94 Scanner 1141G ...
Page 96: ...Scanner 1141 Hardware User Manual 96 Drawing 1 Installation ...
Page 97: ...Appendix B Control Drawings 97 Drawing 2 Power Supply ...
Page 98: ...Scanner 1141 Hardware User Manual 98 Drawing 3 Communications Serial Ports ...
Page 99: ...Appendix B Control Drawings 99 Drawing 4 Status Pulse Inputs Outputs ...
Page 100: ...Scanner 1141 Hardware User Manual 100 Drawing 5 RTD Inputs Analog Inputs Outputs ...
Page 101: ...Appendix B Control Drawings 101 Drawing 6 Analog Outputs ...
Page 102: ...Scanner 1141 Hardware User Manual 102 ...
Page 117: ...117 ...
Page 118: ...118 ...
Page 119: ......
Page 120: ......