OPERATING AND USER MANUAL QUARTZ SERIES
48
Perform flat field correction
Figure 8.3:
Dark scene
Start darkfield
calibration:
FFCAL1*
Calibration done:
FFSTA?
wait
Save darkfield
calibration?
Save darkfield done:
FFSTA?
wait
Brightfield calibration?
Bright scene
Select local (x=0) or global
(x=1) brightfield correction:
FFP101;x
Calibration done:
FFSTA?
wait
Save brightfield
calibration?
Save brightfield done:
FFSTA?
wait
Start
Automatic exposure
adjustment?
Set target exp level
between (x)
50-1023: FFP103;x
Tune video level
between 50-1023
DN
Start brightfield
calibration:
FFCAL3
Save: FFSC0
Save: FFSC1 (or
2,3 or 4)
Enable automatic
exp adjustment:
FFP102;1
Calibration error:
FFERR?
Calibration error:
FFERR?
0 = NO ERROR
NO
10 = BUSY
NO
10 = BUSY
0 = DONE
YES
3 = BUSY
0 = NO ERROR
YES
YES
1 = BUSY
0 = DONE
NO
READY
READY
0 = DONE
NO
YES
0 = DONE
* Also incremental darkfield calibration can be selected
See calibration
error result table
See calibration
error result table