OPERATING AND USER MANUAL QUARTZ SERIES
47
Flat field minimum and maximum video levels
8.3.8.
During global gain flat field calibration (FFCAL), the minimum and maximum video levels are measured
and stored. These video level values can be queried by command:
Command format: FFMINMAX?
Return Message: x;y
Where x and y indicate respectively the minimum level and maximum level.
Returned values are in 10-bit resolution and without the offset as configured by the BL or OFS
command.
Flat field calibration load calibration
8.3.9.
The result of a stored calibration can be retrieved.
Command format: FFLCn
Return Message: n
Where
n = 0 indicates the offset reference image
n = 1…4 indicate one if the available gain calibrations.
Flat field calibration save calibration
8.3.10.
The result of a calibration can be saved.
Command format: FFSCn
Return Message: n
Where
n=0 indicates the offset reference image,
n = 1…4 indicate one if the available gain calibrations.
Storage of a calibration is time consuming; the status of the storage process can be monitored by
the FFSTA? command. The offset reference image (n=0) and the first gain reference (n=1) is pre-
programmed by Adimec; saving sets 0 and / or 1 will overwrite the calibration provided by Adimec.