OPERATING AND USER MANUAL QUARTZ SERIES
37
Sensor reset
Sensor read
Flash strobe
FSM=0 (Auto)
active
delay * 1
µ
s
Timing diagram strobe output (auto mode).
Figure 7.1:
If x is set to 1 the strobe will operate in programmed mode; both delay time after a sensor reset as
well as the duration of the active state is programmed. A new flash window can only start after the
completion of the previous flash strobe window.
Sensor reset
Flash strobe
FSM=1
(
Prog
)
active
delay * 1
µ
s
duration * 1
µ
s
Timing diagram strobe output (programmed mode).
Figure 7.2:
Flash strobe timing
7.5.4.
The strobe output timing can be programmed through the FST command.
Command format: FSTx;y
Command format: FST?
Return Message: x;y
where x indicates the delay time between the sensor reset operation and the active state of the strobe.
y indicates the duration of the strobe if the camera is in programmed strobe timing mode. Note the
duration parameter is ignored in automatic strobe mode.
Valid ranges for both x and y are 0 … 100000. Both x- and y-values are in units of 1µs.
Memory control commands
7.6
Burst count
7.6.1.
The number of images currently stored in the buffer (during burst mode) can be requested from the
camera by the BCNT? command.
Command format: BCNT?
Return Message: n
where n is the actual number of images.