4
ENGLISH
5.4
Minimum thickness and wires
Connections
Cable type
Cable length
1<10 M
Cable length
10<20 M
Cable length
20<30 M
Power supply line, 230/400V 3F
FROR CEI 20-22
CEI EN 50267-2-1
4G 1,5mm²
4G 2,5mm²
4G 4mm²
Power supply line, 230V 2F
3G 1,5mm²
3G 2,5mm²
3G 4mm²
Motors, 230/400V 2F/3F
4G 1mm²
4G 1,5mm²
4G 2,5mm²
Motor, 24V
2 x 1mm²
2 x 1,5mm²
2 x 2,5mm²
Flashing lamp 230V
2 x 0,5mm²
2 x 1mm²
2 x 1,5mm²
Flashing lamp 24V
2 x 0,5mm²
2 x 1mm²
2 x 1,5mm²
Cycle/courtesy lights 230V
3G 0,5mm²
3G 1mm²
3G 1,5mm²
Power supply accessories 24V
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
Warning light 24V
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
Output 24V “in motion”
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
Safety contacts
2 x 0,5mm²
2 x 0,5mm²
2 x 0,5mm²
N.O./N.C. control buttons
2 x 0,5mm²
2 x 0,5mm²
2 x 0,5mm²
End stop
3 x 0,5mm²
3 x 1mm²
3 x 1,5mm²
2nd motor control
1 x 0,5mm²
1 x 0,5mm²
1 x 1mm²
Antenna connection (max 50m)
RG58
Encoder connection (max 30m)
Insulated cable 2402C 22AWG
N.B.: The cross section of cables with lengths other than those listed in the table must be evaluated based on the actual ab-
sorption of the devices connected, in accordance with the recommendations of the CEI EN 60204-1 standard.
For connections that require several loads on the same line (sequential), the sizes listed in the table must be reconsidered
based on the actual absorption and distances.