ENGLISH

SAFETY

The safety features can be connected and designated for:
- Re-opening

Re-opening during closure (2-C1);

- Re-closing

Re-closing during opening  (2-CX, see dip 8-9);

- Partial stop

Partial stop gate stops if in motion with the resulting preparation for automatic closing (2-CX, see dip 8-9);

- Total stop

Total stop (1-2), gate stop, excluding any automatic closing cycle; to resume movement, you must use the pushbutton panel or 

transmitter;

NOTE:

If an N.C. safety contact (2-C1, 2-CX, 1-2) is opened, the LED will fl ash to indicate this fact.

- Obstacle detection.  
With the motor not running (gate closed, open, or after a total stop command), this feature hinders any movement if the safety 
devices (e.g. photoelectric cells) detect an obstacle;
- Safety test function

Safety test function. 

At every gate opening and closure command, the control unit checks the effi ciency of the safety features.
Possible accessories
- Cycle or courtesy lamp

Cycle or courtesy lamp (60W);

OTHER SELECTABLE FUNCTIONS

- Automatic closure.  The automatic closure timer self-powers at the opening end stop. The modifi able set time is also subject to 
modifi cations due to the intervention of possible safety accessories. This does not happen following a complete “stop” command 
or if power is cut;
- Partial opening

Partial opening. Opening of the gate to allow for pedestrian traffi c; activated by connecting to clamps 2-3P and adjusted with 

the PART. OP. trimmer.  With this function, the automatic closing can vary in the following way:
1) Dip 12 set to ON: after a partial opening, the time for automatic closing functions independently of the adjustment of the TCA 
trimmer and of the position of Dip 1; it is set at 8 seconds.
2) Dip 12 set to OFF: after a partial opening, the time for automatic closing is adjustable only if Dip 1 is set to ON;
- Cycle lamp

Cycle lamp.  A light that illuminates the manoeuvring zone: it remains lit from the moment the doors begin to open until they 

are completely closed (including the time required for the automatic closure). 
If automatic closing is not activated, the lamp remains on only during movement (E-EX);
- Courtesy Light

Courtesy Light.  A light that illuminates the manoeuvring zone: after an opening command, the light remains on for a fi xed time 

of 5 minutes and 30 seconds (E-EX); 
- “Maintained Action” function. Gate operation while keeping the pushbutton pressed (excludes the radio-control operation);
-   Pre-fl ashing;

Pre-fl ashing;  5 seconds pre-fl ash during both opening and closing of the wing;

  - Master function;  the panel assumes all the command functions when two paired motors are used (see page 30);
  - Slave function;  this panel is exclusively controlled by the “MASTER”;
- Enabling functions

Enabling functions of partial stop or closure whilst opening, normally-closed contact (2-CX), select one of the two functions by 

setting Dip 
(see Function selections);
  -Type of command

Type of command: 

-open-close-reverse by button and transmitter;
-open-stop-close-stop by button and transmitter;
-open only by transmitter.

ADJUSTMENTS

- automatic closing time; 
- Partial opening time.

5.7 Dip-Switches and functions

Summary of Contents for ZT6

Page 1: ...ZT6 ZT6C INSTALLATION MANUAL Control panel for BK220T CBYT CBXT...

Page 2: ...cessories fuse 3 315mA Control unit fuse 4 8A F Line fuse 5 Radio frequency card connector see table point 5 10 6 Radio code signal LED 7 Connecting terminal boards 8 Connecting terminal boards transf...

Page 3: ...the contacts to shunt the power supply Check that the connections inside the case executed for continuity of the protection circuit are allowed provided they have supplementary isolation with respect...

Page 4: ...0V 3G 0 5mm 3G 1mm 3G 1 5mm Power supply accessories 24V 2 x 0 5mm 2 x 0 5mm 2 x 1mm Warning light 24V 2 x 0 5mm 2 x 0 5mm 2 x 1mm Output 24V in motion 2 x 0 5mm 2 x 0 5mm 2 x 1mm Safety contacts 2 x...

Page 5: ...ly 400V AC three phase 380 COM and 230V AC three phase 220 COM Single phase three phase motor 230 400V AC max 750 W Cycle or courtesy lamp 230V Cycle lamp Dip 16 OFF Dip 17 ON Courtesy light Dip 16 ON...

Page 6: ...the case of additions to make in parallel dy connected in the case of additions to E4 10 11 TS 1 2 3 3P 4 5 6 7 2Mot 2 C1 CX B1 B2 FC FA F R S R S T U W V E E1 E EX Power supply 230V AC single phase 2...

Page 7: ...nd adjusted with the PART OP trimmer With this function the automatic closing can vary in the following way 1 Dip 12 set to ON after a partial opening the time for automatic closing functions independ...

Page 8: ...y device on clamps 2 CX activated if the devices on the 2 CX clamps are not used set Dip 8 to ON 10 OFF Total stop function connect the button onto clamps 1 2 activated 10 ON deactivated 11 OFF Slave...

Page 9: ...to make it inoperable slave 1 Make sure that the radiofrequency card is only inserted on the MASTER board 2 make the electrical connections and the normally used selections only on the MASTER termina...

Page 10: ...D INSERTION TOP TAM For transmitters with 433 92 Supereterendina frequency TOP and TAM series position the jumper as illustrated on the respective AF 43S card SCHEDA BASE SHEDA AF The AF board should...

Page 11: ...side the package TAM T432 T434 T438 See instruction sheet inside the package TFM T132 T134 T138 T152 T154 T158 See instruction sheet inside the package STANDARD ENCODING PROCEDURE 1 assign a code also...

Page 12: ...rried out whilst keeping the jumpers po sitioned for channels 1 and 2 as per g A see g B for any subsequent settings on different channels TOP T262M T302M FIG A FIG B T264M T304M T2622M T3022M P1 CH1...

Page 13: ...ey pressed on the base card and after the LED signal lights up send a command using the transmitter key The LED will ash brie y to signal that the code has been memorized see g 1 Perform the same proc...

Page 14: ...EN 60335 1 SAFETY IN APPARATUSES FOR HOME USE EN 60204 1 MACHINERY SAFETY EN 61000 6 2 ELECTROMAGNETIC COMPATIBILITY EN 61000 4 4 ELECTROMAGNETIC COMPATIBILITY EN 61000 4 5 ELECTROMAGNETIC COMPATIBILI...

Page 15: ...15 All the data and information contained herein is considered subject to change at any time and at our discretion ENGLISH...

Page 16: ...Cod 319T90 R0 1 09 05 CAME CANCELLI AUTOMATICI CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431...

Reviews: