6

            

ENGLISH

Power supply  

accessories 24V (AC) 

Output 24V (AC)  

in motion

Warning light (24V-3W max.) 

“gate open”

Warning light (24V-3W max.) 

“gate closed”

Stop button (N.C.) Emergency button  

already connected, in the event of additions 

Stop button (N.C.) Emergency button  

Stop button (N.C.) Emergency button  
connected in series

already connected, in the event of additions 

already connected, in the event of additions 

Open button (N.O.) Opening button already 

connected, in the case of additions to make 

in parallel.

Button for partial opening (N.O.)

Closing button (N.O.) Closing button alrea-

dy connected in the case of additions to 

Closing button (N.O.) Closing button alrea-

Closing button (N.O.) Closing button alrea-
make in parallel

dy connected in the case of additions to 

dy connected in the case of additions to 

E4 10 11 TS 1

2 3 3P 4

5

6

7

2Mot

2 C1 CX B1 B2

FC FA F

R
S

R
S

T

U

W

V

E

E1

E

EX

Power supply: 230V (AC) single-phase (220-Com)

Power supply: 400V (AC) three-phase (380-COM) and 230V (AC) three-phase (220-COM)

Single-phase/three-phase motor 230/400V (AC) max.750 W

Cycle or courtesy lamp (230V)  (Cycle lamp Dip 16 OFF Dip 17 ON)-(Courtesy light  Dip 16 ON 

Dip 17 OFF) max 60 W.

Output 230V (AC.) in motion (e.g. fl ashing lamp - max. 25W)

10
11

1
2

2
3

2

3P

5

11

6

11

Radio contact and/or control button

(see dip-switch 2-3 sel. functions)

Contact (N.C.) «Re-closing during 

opening»*Dip 8 OFF and Dip 9 OFF)

Contact (N.C.) partial stop (Dip 8 OFF Dip 9 ON

Contact (N.C.) of «Re-opening during 

closure

Contact (N.C.) of «Re-opening during 

Contact (N.C.) of «Re-opening during 

End stop connection closes

End stop connection opens

Contact outlet (N.O.) Contact capacity:  5A  
at 24V (DC)

Connection of antenna

Output for control of 2 coupled motors

10
E4

2
4

2
7

2

C1

2

CX

B1
B2

2MOT

F

FA

F

FC

}

Max.20 W totali


5

            

            

            

            

.6

            

            

            

            

ZT6C electrical connections 

            

            

            

            

Summary of Contents for ZT6

Page 1: ...ZT6 ZT6C INSTALLATION MANUAL Control panel for BK220T CBYT CBXT...

Page 2: ...cessories fuse 3 315mA Control unit fuse 4 8A F Line fuse 5 Radio frequency card connector see table point 5 10 6 Radio code signal LED 7 Connecting terminal boards 8 Connecting terminal boards transf...

Page 3: ...the contacts to shunt the power supply Check that the connections inside the case executed for continuity of the protection circuit are allowed provided they have supplementary isolation with respect...

Page 4: ...0V 3G 0 5mm 3G 1mm 3G 1 5mm Power supply accessories 24V 2 x 0 5mm 2 x 0 5mm 2 x 1mm Warning light 24V 2 x 0 5mm 2 x 0 5mm 2 x 1mm Output 24V in motion 2 x 0 5mm 2 x 0 5mm 2 x 1mm Safety contacts 2 x...

Page 5: ...ly 400V AC three phase 380 COM and 230V AC three phase 220 COM Single phase three phase motor 230 400V AC max 750 W Cycle or courtesy lamp 230V Cycle lamp Dip 16 OFF Dip 17 ON Courtesy light Dip 16 ON...

Page 6: ...the case of additions to make in parallel dy connected in the case of additions to E4 10 11 TS 1 2 3 3P 4 5 6 7 2Mot 2 C1 CX B1 B2 FC FA F R S R S T U W V E E1 E EX Power supply 230V AC single phase 2...

Page 7: ...nd adjusted with the PART OP trimmer With this function the automatic closing can vary in the following way 1 Dip 12 set to ON after a partial opening the time for automatic closing functions independ...

Page 8: ...y device on clamps 2 CX activated if the devices on the 2 CX clamps are not used set Dip 8 to ON 10 OFF Total stop function connect the button onto clamps 1 2 activated 10 ON deactivated 11 OFF Slave...

Page 9: ...to make it inoperable slave 1 Make sure that the radiofrequency card is only inserted on the MASTER board 2 make the electrical connections and the normally used selections only on the MASTER termina...

Page 10: ...D INSERTION TOP TAM For transmitters with 433 92 Supereterendina frequency TOP and TAM series position the jumper as illustrated on the respective AF 43S card SCHEDA BASE SHEDA AF The AF board should...

Page 11: ...side the package TAM T432 T434 T438 See instruction sheet inside the package TFM T132 T134 T138 T152 T154 T158 See instruction sheet inside the package STANDARD ENCODING PROCEDURE 1 assign a code also...

Page 12: ...rried out whilst keeping the jumpers po sitioned for channels 1 and 2 as per g A see g B for any subsequent settings on different channels TOP T262M T302M FIG A FIG B T264M T304M T2622M T3022M P1 CH1...

Page 13: ...ey pressed on the base card and after the LED signal lights up send a command using the transmitter key The LED will ash brie y to signal that the code has been memorized see g 1 Perform the same proc...

Page 14: ...EN 60335 1 SAFETY IN APPARATUSES FOR HOME USE EN 60204 1 MACHINERY SAFETY EN 61000 6 2 ELECTROMAGNETIC COMPATIBILITY EN 61000 4 4 ELECTROMAGNETIC COMPATIBILITY EN 61000 4 5 ELECTROMAGNETIC COMPATIBILI...

Page 15: ...15 All the data and information contained herein is considered subject to change at any time and at our discretion ENGLISH...

Page 16: ...Cod 319T90 R0 1 09 05 CAME CANCELLI AUTOMATICI CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431...

Reviews: