ENGLISH
Power supply
accessories 24V (AC)
Output 24V (AC)
in motion
Warning light (24V-3W max.)
“gate open”
Warning light (24V-3W max.)
“gate closed”
Stop button (N.C.)
Open button (N.O.)
Button for partial opening (N.O.)
Closure button (N.O.)
5.5 ZT6 Electrical connections
E4 10 11 TS 1
2 3 3P 4
5
6
7
2Mot
2 C1 CX B1 B2
FC FA F
Position the exposed control buttons, located 1.5 m from the ground and distant from mobile parts of the automation
R
S
R
S
T
U
W
V
E
E1
E
EX
Power supply: 230V (AC) single-phase (220-COM)
Power supply: 400V (AC) three-phase (380-COM) and 230V (AC) three-phase (220-COM)
Single-phase/three-phase motor 230/400V (AC) max.750 W
Cycle or courtesy lamp (230V) (Cycle lamp Dip 16 OFF Dip 17 ON)-(Courtesy light Dip 16 ON
Dip 17 OFF) max 60 W.
Output 230V (AC) in motion (e.g. fl ashing lamp - max. 25W)
10
11
1
2
2
3
2
3P
5
11
6
11
Radio contact and/or control button
(see dip-switch 2-3 sel.functions)
Contact (N.C.) «Re-closing during
opening»*Dip 8 OFF and Dip 9 OFF)
Contact (N.C.) partial stop (Dip 8 OFF Dip 9 ON
Contact (N.C.) of «Re-opening during
closure
Contact (N.C.) of «Re-opening during
Contact (N.C.) of «Re-opening during
End stop connection closes
End stop connection opens
Contact outlet (N.O.) Contact capacity: 5A
at 24V (DC)
Connection of antenna
Output for control of 2 coupled motors
10
E4
2
4
2
7
2
C1
2
CX
B1
B2
2MOT
F
FA
F
FC
}
Max.20 W totali