Page
25
- Manual
FA01748-EN
- 04/2023 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Sensor type
Choose the type of access device.
F14
1 = Keypad (Default)
0 = Transponder
LED strip light management
Choose the operating mode for the LED strip light.
F15
0 = bi-colour LED strip light (default)
1 = White LED strip light
Light E1
Choose the type of device connected to output E1.
F18
0 =Flashing beacon (Default)
1 = Cycle light
The lamp stays on during the manoeuvre.
This parameter does not appear if there [Automatic Close] function is deactivated.
2 = Courtesy lamp
The light switches on when a manoeuvre starts and remains on once the manoeuvre has finished, for the time set under the
function [F25 Courtesy time].
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
F19
OFF (Default)
From 1 to 180 seconds
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
OFF (Default)
1 to 10 seconds
Courtesy time
Set the lighting device operation time.
F25
60 to 180 seconds (Default 180 seconds)
Opening speed
Set the opening speed as a percentage.
For booms complete with accessories (swing rest and/or skirt), reduce the speed.
F28
50% to 100% (Default 70%)
Closing speed
Set the closing speed (percentage of maximum speed).
For booms complete with accessories (swing rest and/or skirt), reduce the speed.
F29