Maximum capacity of contacts
The total power of the outputs listed below must not exceed the maximum output power [Accessories]
Device
Output
Power supply (V)
Maximum power (W)
Accessories
10 - 11
24 AC
40
Flashing beacon
10 - E1
24 AC
15
Passage-open warning light
10 - 5
24 AC
3
The outputs deliver 24 V DC when the batteries start operating, if they are installed.
Command and control devices
1
STOP button (NC contact)
This stops the boom and excludes automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during programming.
2
Control device (NO contact)
OPEN ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during OPENING.
3
Control device (NO contact)
PARTIAL OPENING function
The contact must only be used for operators working in paired mode.
4
Control device (NO contact)
CLOSE ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during CLOSING.
5
Control device (NO contact)
OPEN-CLOSE function
6
Card reader
Insert the R700 card into the corresponding connector.
7
Transponder selector switch
Insert the R700 card into the corresponding connector.
8
Keypad selector
Insert the R800 card into the corresponding connector.
9
Antenna with RG58 cable
Insert the AF card into the corresponding connector for remote control with transmitter.
S 1
2
3 3P 4
5
7
2 CX CY CZ
A
B
S1 GND