Remove user
Remove one of the registered users.
U2
OFF (Default)
ON
No. 1 > 250
Use the arrows to choose the number associated with the user you want to remove.
Alternatively, the control device associated with the user you want to remove can be activated.
Press ENTER to confirm.
“CLr” will appear to confirm deletion.
Remove all
Remove all registered users.
U3
OFF (Default)
ON
Radio decoding
Choose the type of radio coding for the transmitters enabled to control the operator.
If you choose the type of radio coding for the transmitters [Rolling code] or [TW key block], any transmitters with a different type of radio coding saved previously
will be deleted.
U4
1 = All decoding (default)
2 = Rolling code
3 = TW key block
Self-Learning Rolling
Save a new rolling code transmitter by activating acquisition from a rolling code transmitter that has already been saved. The saving and acquisition procedures are
explained in the transmitter manual.
U8
OFF (Default)
ON
Boom length
Set the boom length.
A1
3 = 3 m boom
4 = 4 m boom
Motor test
Check the boom opens in the correct direction.
If the keys do not execute the commands correctly, invert the boom opening direction.
A2
The button > makes the motor turn in clockwise direction.
The button < makes the motor turn in an anticlockwise direction.
Travel calibration
Start the travel self-learning.
A3
ON (Run operation)
OFF (Cancel operation)
Parameter reset
Restore factory settings except for the functions: [Radio decoding], [Boom length] and the settings related to travel calibration.
A4
OFF (Default)