PRODUCT DATA AND INFORMATION
Key
This symbol shows which parts to read carefully.
This symbol shows which parts describe safety issues.
This symbol shows what to tell users.
The measurements, unless otherwise stated, are in millimetres.
Description
803BB-0370
GLT40AOS - Automatic barrier with irreversible gearmotor 24 V DC with encoder; painted galvanised steel cabinet; accessories available. Balance spring included.
803BB-0380
GLT40ROS - Automatic barrier with irreversible gearmotor 24 V DC with encoder; painted galvanised steel cabinet; accessories available. Balance spring included.
803BB-0390
GLT40ACS - Automatic barrier with irreversible gearmotor 24 V DC with encoder; custom-RAL painted galvanised steel cabinet; accessories available. Balance spring
included.
803BB-0400
GLT40AX4 - Automatic barrier with irreversible gearmotor 24 V DC with encoder; satin-finish AISI 304 steel cabinet; accessories available. Balance spring included.
Intended use
The ideal solution for access roads with heavy transit flows
Any installation and/or use other than that specified in this manual is forbidden.
Usage limitations
MODELS
GLT40AOS
GLT40ROS
GLT40ACS
GLT40AX4
Max. net clearance width (m)
4
4
4
4
Technical data
MODELS
GLT40AOS
GLT40ROS
GLT40ACS
GLT40AX4
Power supply (V - 50/60 Hz)
220-230 AC
120 AC
220-230 AC
220-230 AC
Maximum current draw (A)
0,8
1,6
0,8
0,8
Motor power supply (V)
24 DC
24 DC
24 DC
24 DC
Standby consumption (W)
7
7
7
7
Power (W)
190
190
190
190
Operating temperature (°C)
-20 ÷ +55
(-40 with item 803XA-
0630)
-20 ÷ +55
(-40 with item 803XA-
0630)
-20 ÷ +55
(-40 with item 803XA-
0630)
-20 ÷ +55
(-40 with item 803XA-
0630)
Torque (Nm)
140
140
140
140
Opening time at 90° (s)
2 ÷ 6
2 ÷ 6
2 ÷ 6
2 ÷ 6
Cycles/hour
300
300
300
300
Cycles/day
5400
5400
5400
5400
Protection rating (IP)
54
54
54
54
Insulation class
I
I
I
I
Weight (kg)
56
56
56
56
Storage temperature (°C)*
-20 ÷ +70
-20 ÷ +70
-20 ÷ +70
-20 ÷ +70
Average life (cycles)**
1.500.000
1.500.000
1.500.000
1.500.000
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very high or very low temperature.
(**) The average product life specified should be understood purely as an indicative estimate. It applies to normal usage conditions and where the product has been
installed and maintained in compliance with the instructions provided in the CAME technical manual. The average product life is also affected, including significantly,
by other variables such as, but not limited to, climatic and environmental conditions. The average product life should not be confused with the product warranty.
Fuse table
MODELS
GLT40AOS
GLT40ROS
GLT40ACS
GLT40AX4
Line fuse
1.6 A-F
3.15 A-F
1.6 A-F
1.6 A-F
Accessory fuse
2 A-F
2 A-F
2 A-F
2 A-F
Control board fuse
4 A-F
4 A-F
4 A-F
4 A-F
Motor fuse
10 A-F
10 A-F
10 A-F
10 A-F