Manoeuvre counter
View the number of total or partial operator manoeuvres (after maintenance).
The number of manoeuvres is the number shown multiplied by 1000.
A5
Tot = total manoeuvres
Manoeuvres performed since the operator was installed.
Par = partial manoeuvres
Under the [Par] parameter, press the ENTER key to reset the number of partial manoeuvres. [Clr] will appear on the
screen to confirm deletion.
FW version
Display the firmware version number.
H1
Enable password
Set a 3-digit password. The password will be requested to anyone who wants to access the main menu.
Remove the password that protects access to the main menu.
H3
ON
Use the arrows and the Enter button to dial the desired code.
OFF
Press ENTER to confirm deletion.
Forgotten password
If you forget your password, follow the procedure below.
Disconnect the control board from the power supply.
Press and hold the < and > buttons, then reconnect the control board to the power supply.
Continue to press and hold the < > buttons until [ON/OFF] is displayed.
Select [ON].
Press ENTER to confirm.
When you reset the control board, all saved users, set times and calibration operations are deleted.
Import/export data
1
Insert the MEMORY ROLL card into the corresponding connector on the control
board.
2
Press the “Enter” button to access programming.
3
Use the arrows to choose the desired function.
The functions are displayed only when a MEMORY ROLL card is inserted.
-Save data
Save user data, timings and configurations to the memory device (memory roll or
USB key).
-Read data
Upload user data, timings and configurations from the memory device (memory roll
or USB key).
Before inserting and removing the MEMORY ROLL card, DISCONNECT THE
MAINS POWER SUPPLY TO THE LINE.
Remove the MEMORY ROLL card after the data has been loaded.