MCBF
Models
GPT40
Std boom L = 3.05 m
4.000.000
Boom L = 4.05 m
-0 %
Boom L = 3.05 m with joint
-0 %
Boom L = 4.05 m with joint
-0 %
The GARD PT barrier has been designed to perform up to 4 million cycles. Thanks to its ultra-efficient brushless motor, it is extremely reliable and
requires very little maintenance.
The MCBF value relates to the barrier only and does not refer to any applicable accessories.
The percentages indicate how much the number of cycles should be reduced in relation to the type and number of accessories installed.
The installer is responsible for deciding on the type of intervention and the maintenance frequency, considering the use, installation site and number of daily
cycles.
If the barrier is not used for long periods of time, e.g. for installations at sites with seasonal closures, release the spring and remove the boom.
For information on correct installation and adjustments, please see the product installation manual.
For information on choosing products and accessories, please see our product catalogue.
If the barrier with an articulated joint is used, check that the moving parts of the joint are in good condition. Replace them if necessary.
Every 500,000 cycles and, in any case, every 6 months of operation, you must perform the maintenance work indicated below.
- Perform a general and complete check of the tightness of the nuts and bolts.
- Check the warning and safety devices are working properly.
- Check that the microswitch connected to the cabinet cover is working correctly.
- Check the microswitch connected to the manual release is working properly, and the microswitch connected to the release accessories (optional).
- Lubricate the spring when it is fully extended.
- Grease all of the moving mechanical parts.
- Grease the electric lock and the pin.
Every 1,000,000 cycles and, in any case, every 12 months of operation, you must perform the maintenance work indicated below.
- Replace the spring.