RSE speed
Set the remote connection system communication speed on the RSE1 port.
F63
RSE speed
0 = 1200 bps
1 = 2400 bps
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (default)
7 = 57600 bps
8 = 115200 bps
FCA FCC warnings
Configure the method with which the FCA and FCC outputs report the boom status.
F70
FCA FCC warnings
OFF (Default)
1 = Impulse
When the boom reaches the travel end point (while opening or closing), the FCA-CM1
or FCC-CM2 contact closes for one second.
2 = Steady
When the boom reaches the travel end point (while opening or closing), the FCA-CM1
or FCC-CM2 contact closes and remains closed.
3 = Custom
The FCA-CM1 contact is closed with the boom in the open travel end position and
during the opening manoeuvre. The FCC-CM2 contact is closed with the boom in the
closed travel end position and during the closing manoeuvre.
Opening counter
With the function active, you can send a series of opening commands corresponding to the number of vehicles which have to be authorised to pass through the
gate. The function can only be operated by control devices connected to the contact 2-3. The magnetic contact, to which the loop that counts vehicles in transit is
connected, is connected to an input. This input must be programmed to operate in C5/C9/C10 mode. At the end of the count the passage is closed.
F75
Opening counter
OFF (Default)
ON
Boom drop-away detection
Activate the contact on the ARM terminal board for detecting the boom drop-away.
F78
Boom drop-away detection
OFF (default)
ON
New user
Register up to a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter or another control device. The boards that manage the control devices (AF - R700 - R800) must
be inserted into the connectors.
Download the LIST OF REGISTERED USERS form from the docs.came.com portal by typing in L20180423.
U1
New user
1 = Step-by-step
3 = Open
4 = Partial opening
When the barrier is in [Paired] mode, the [Partial Opening] command opens the Master
barrier.
1 -Choose the function to be assigned to the user.
2 -Press ENTER to confirm.
You will be asked to enter your user code.
3 -Send the code from the control device.
Repeat the procedure to add other users.