CY input
Associate a function with the CY input.
F3
CY input
OFF (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopen while closing (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during
closure
C10 = Immediate closure during opening with obstacle standby during closure (NO
contact)
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
CZ input
Associate a function with the CZ input.
F4
CZ input
OFF (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopen while closing (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during
closure
C10 = Immediate closure during opening with obstacle standby during closure (NO
contact)
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
F5
Safety devices test
OFF (Default)
1 = CX
2 = CY
3 = CZ
4 = CX+CY
5 = CX+CZ
6 = CY+CZ
7 = CX+CY+CZ
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
F6
Hold-to-run
OFF (Default)
ON
Obstacle with motor stopped
With the function active, the boom remains stopped if the safety devices detect an obstacle. The function activates with: closed boom, open boom or after a
complete stop.
F9
Obst. with motor stopped
OFF (Default)
ON