P
age
24
- Manual
FA01440-EN
- 07/2020 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Remove user
Remove one of the registered users.
U2
Remove user
OFF (Default)
ON
No. 1 > 250
Use the arrows to choose the number associated with the user you want to remove.
Alternatively, the control device associated with the user you want to remove can be
activated.
Press ENTER to confirm.
Remove all
Remove all registered users.
U3
Remove all
OFF (Default)
ON
Radio decoding
Choose the type of radio coding for the transmitters enabled to control the operator.
If you choose the type of radio coding for the transmitters [Rolling code] or [TW key block], any transmitters with a different type of radio coding saved
previously will be deleted.
U4
Radio decoding
1 = All (Default)
2 = Rolling code
3 = TW key block
Boom length
Set the boom length.
A1
Boom length
1 = up to 2.5 m (Default)
2 = from 2.5 to 3.8 m
Motor test
Check the boom opens in the correct direction.
If the keys do not execute the commands correctly, invert the boom opening direction.
A2
Motor test
ON = to activate the TEST.
The button > makes the motor turn in clockwise direction.
The button < makes the motor turn in an anticlockwise direction.
Travel calibration
Start the travel self-learning.
A3
Travel calibration
ON = To start calibration
Parameter reset
Restore factory settings except for the functions: [Radio decoding], [Boom length] and the settings related to travel calibration.
A4
Parameter reset
OFF (Default)
ON
Manoeuvre counter
View the number of manoeuvres performed by the operator (1 = 1000 manoeuvres).
A5
Manoeuvre counter