Pa
g.
44
- M
an
u
al
c
od
e:
11
9
D
U
6
4
11
9
D
U
6
4
ve
r.
3
3
0
5
/2
0
13 © C
A
M
E c
an
ce
lli
auto
m
ati
ci
s.p.a. - T
h
e d
ata a
n
d i
nf
or
m
ati
on r
ep
orte
d i
n th
is
in
sta
lla
tio
n m
an
u
al
a
re s
u
sc
ep
tib
le to c
h
an
g
e at a
ny ti
m
e a
n
d w
ith
ou
t o
b
lig
ati
on
o
n C
A
M
E c
an
ce
lli
auto
m
ati
ci
s.p.a. to n
otify u
se
rs.
ENGLISH
N.B. The cable section, with different lengths from those shown on the table, must be considered on the basis the actual draw of
the connected devices, according to what is prescribed in the CEI EN 60204-1 Code.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power
draw and distances. When connecting products that are not specified in this manual, please follow the documentation provided
with said products.
5.2 Cable list and minimum thickness
Connections
Type of cable
Length of cable
1 < 10 m
Length of cable
10 < 20 m
Length of cable
20 < 30 m
Control panel power supply 230 V
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
Motor power supply 230 V
3 x 0,5
mm2
3 x 0,5 mm
2
3 x 0,5 mm
2
Flashing light
2 x 0,5 mm
2
2 x 1 mm
2
2 x 1,5 mm
2
Photocell transmitters
2 x 0,5 mm
2
2 x 0.5 mm
2
2 x 0,5 mm
2
Photocell receivers
4 x 0,5 mm
2
4 x 0,5 mm
2
4 x 0,5 mm
2
Accessories power supply
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Control and safety devices
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Antenna
RG58
max. 10 m
Encoder connection
TWISTATO
3 x 0,5 mm
2
5 Installation
Before installing, do the following:
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage;
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage.
•
Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra
insulation as compared to the other conductive parts inside;
• Make sure the structure of the gate is sturdy, the hinges work and that there is no friction between moving and non-moving
parts;
• Make sure that there are mechanical endstops for both opening and closing runs.
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
5.1 Preliminary checks
Summary of Contents for F7001
Page 3: ......
Page 19: ...F7001 F7001E English EN 119DU64EN AUTOMATION FOR SWING GATES INSTALLATION MANUAL ...
Page 21: ......
Page 37: ...F7001 F7001E Français FR 119DU64FR AUTOMATISME POUR PORTAILS BATTANTS MANUEL D INSTALLATION ...
Page 39: ......
Page 55: ...F7001 F7001E 119DU64RU Русский RU АВТОМАТИКА ДЛЯ РАСПАШНЫХ ВОРОТ ИНСТРУКЦИЯ ПО МОНТАЖУ ...
Page 57: ......