Chapter 4: Legal and regulatory information
Compliance with safety standards
Page 4-25
Table 87
FCC minimum safe distances – PMP 450m 5.1 GHz, 5.2 GHz, 5.4 GHz and 5.8 GHz
Band
(GHz)
Antenna
PG (W)
S (W/ m
2
)
d (m)
5.1
90° sector
3.38
10
0.16
5.2
90° sector
0.85
10
0.08
5.4
90° sector
0.85
10
0.08
5.8
90° sector
3.38
10
0.16
Summary of Contents for PMP 450 AP
Page 1: ...33F Cambium 450 Platform User Guide System Release 15 2 pass...
Page 14: ...Contents Page xii 450m overload I Glossary III...
Page 104: ...Chapter 2 System hardware Cabling Page 2 40...
Page 157: ...Chapter 3 System planning Radio Frequency planning Page 3 24 Figure 49 Sector Antenna...
Page 158: ...Chapter 3 System planning Radio Frequency planning Page 3 25 Figure 50 cnMedusa Antenna...