Table 74
PMP/PTP 450 Series wind loading (lb force)
Type of ODU
Max surface area
(square feet)
Wind speed (miles per hour)
100
105
110
115
120
External 60º sector
antenna – 2.4 GHz
AP
2.9
122
134
147
161
175
External 60º sector
antenna – 5 GHz AP
0.71
29.8
33
37
39
43
External 90º sector
antenna – 5 GHz AP
0.89
37
41
45
49
54
SM
0.29
12
13
15
16
18
Integrated High-
Gain, Ruggedized
1
42
46
51
56
60
Integrated Dish
1.49
63
69
76
83
90