Power Planning
IMPORTANT!
The power supply or supplies for the CMM4 must be separately
ordered – no power supplies are included under model numbers
1090CK, 1091, or 1092. (This differs from the CMMmicro where the
power supply is included when model number 1070CK is ordered.) See
for pictures of the 30 VDC and 54 VDC supplies and for power
supply part numbers.
A 30 VDC power supply is needed for the following equipment:
•
PMP 100 FSK regular and Advantage APs
•
PMP 54400 OFDM APs
•
PTP 100 FSK BHs
•
PTP 54200 OFDM BHs
•
PMP 450 Series OFDM APs
•
ePMP Series
A 54 VDC power supply is needed for the following equipment:
•
PMP 320 802.16e APs
•
PMP 430 OFDM APs
•
PMP 49400 OFDM APs
•
PTP 49200 OFDM BHs
•
PMP 450i OFDM APs (requires crossover cable N000045L001A for Ethernet
•
connection)
NOTE:
I
n most cases SMs use the same voltage as their associated APs. Three
exceptions to be aware of are
◦ PMP 320 SMs use 802.3af power supplies
◦
PMP 430 SMs use 30 VDC power supplies.
◦
PMP 450 900 MHz SMs use 30 VDC power supplies
There are four input power terminal blocks inside the CMM4. Two of them are for 29/30 VDC
input, and the other two are for 56 VDC input. The two 29 VDC terminal blocks and the two 56 VDC
terminal blocks allow the CMM4 to be powered from redundant power supplies, if so desired.