PMP Synchronization Solutions User Guide
Installing a CMM4
PMP-0297 007v001 (January, 2017)
3-59
Perform the following procedure to install the CMM4.
Procedure 13 Mounting the CMM4
1
Ensure that the mounting position
•
is not
further than 328 feet (100 meters) from the furthest AP or BH that the CMM4 will
serve.
•
is not
closer than 10 feet (3 meters) to the nearest AP or BH.
•
is not
further than 100 feet (30.5 meters) of cable from the intended mounting position
of the GPS antenna.
•
allows you to fully open the door for service.
2
Select a support structure to which the flanges can be mounted.
3
If the support structure is a wall, use screws or bolts (neither is provided) to attach the
flanges to the wall.
If the support structure is an irregular-shaped object, use adjustable stainless steel bands
(provided) to attach the CMM4 to the object.
If the support structure is a pole that has an outside diameter of 1.25 to 3 inches (3 to 8 cm),
use a toothed V-bracket (provided) to
•
attach the V-bracket to the pole as shown below.
•
attach the CMM4 flanges to the V-bracket.
Figure 58 CMM4 V-bracket to pole mounting