PMP Synchronization Solutions User Guide
Installing a CMM4
PMP-0297 007v001 (January, 2017)
3-64
7
Consistent with practices in your company, note the above information to add later to the
company equipment database.
8
Connect the coax cable from the female N-connector on the GPS antenna to the female N-
connector on the outside of the CMM4.
9
Ensure there is an Ethernet cable between the management port on the controller board
and one of the Ethernet ports on the EtherWAN switch.
10
Feed the DC power cord through a cable gland. A 1-hole gland insert is provided, as the DC
power cable is too thick to share a gland with other cables. The 1-hole insert is either
connected to one of the patch cables or included in the parts bag.
11
For 29 V: Connect the white wire to +29V on either of the 29 VDC terminal blocks.
12
Connect the black wire to - V (GND) on the same 29 VDC terminal block.
13
For 56V: Connect the black and white wire to +56V on either of the 56 VDC terminal blocks.
14
Connect the black wire to –V (GND) on the same 56 VDC terminal block.
15
Plug the DC power supply into an AC receptacle (AC mains).
16
Verify that the LEDs light.
The indicator LEDs are shown in
. Color indicates position, but not state. For example,
the red Power LED, in the left most position, lights when power is applied to the unit, but does not
change color at any point.
Figure 63 CMM4 LED indicators