EN
I-MAT_Ed6 - Operating Instructions
Page 31 / 164
Through this button you have access to
the frequency converter programming
parameters. If you already are on the
programming functions, by pushing this
button you go up on the menu
Through this button you have access
to frequency converter programming
parameters. If you changed a parameter,
by pushing this button you can confirm
the indicated value.
Through this button you can decrease
parameters or to change the visualized
parameter.
Through this button you can increase
parameters or to change the visualized
parameter.
P460
4.93.410
3.6. Interface
The graphic interface of the display is divided in
three visualization areas:
System icons
Display area
Operating icons
3.7. System icons
AUTO MODE
The system is operating in auto mode
MANUAL MODE
The system is operating in manual mode
SET-UP MODE ACTIVATED
It shows that the set-up menu is
activated. When an icon is blinking you
are modifying a parameter. You can
confirm with ENTER.
ALARM
It indicates that there is a fault on the
system, the error number appears on
the display. When you are on the setup
mode the alarm icon will not appear. If it
is blinking it indicates a warning.
SENSOR STATE
It indicates that the system is connected
to the transducer, if it is blinking there is
a fault on the transducer.
PUMP STATE
It indicates if the pump is running or in
standby state
CASCADE MODE
It indicates that the cascade control
mode is working. The 2 upper symbols
shows if the pump is in stand-by. The
lower symbol informs if the pump is the
master (lit icon) or slave (blinking icon)
3.8. Display area
It is composed from an incremental bar proportional
with the displayed value and its measure unit. The
display is backlit, the light will turn off after 20
seconds of system inactivity.
3.9. Operating icons
Constant pressure mode
The system keeps the pressure
constant when the quantity of water
requested by the user changes.
Proportional pressure mode
The system keeps the pressure
proportional to the quantity of water
requested by the user.
Constant temperature mode
The system keeps the temperature
constant at a set point.
Constant flow mode
The system keeps the flow constant.
Fixed speed mode
The system works at a fixed speed that
user can choose according to need.
I-MAT_Ed6.indd 31
I-MAT_Ed6.indd 31
18/11/20 08:20
18/11/20 08:20
Summary of Contents for I-MAT 11,2 TT-B
Page 2: ...I MAT_Ed6 indd 2 I MAT_Ed6 indd 2 18 11 20 08 20 18 11 20 08 20...
Page 146: ...RU C 146 164 I MAT_Ed6 16 I MAT_Ed6 indd 146 I MAT_Ed6 indd 146 18 11 20 08 21 18 11 20 08 21...
Page 160: ...160 164 I MAT_Ed6 I MAT_Ed6 indd 160 I MAT_Ed6 indd 160 18 11 20 08 22 18 11 20 08 22...
Page 161: ...I MAT_Ed6 161 164 I MAT_Ed6 indd 161 I MAT_Ed6 indd 161 18 11 20 08 22 18 11 20 08 22...
Page 163: ...I MAT_Ed6 indd 163 I MAT_Ed6 indd 163 18 11 20 08 22 18 11 20 08 22...