6.4.3. Delivery pipe

Fit a gate valve in the delivery pipe to adjust delivery,
head, and absorbed power.
Install a pressure gauge.
With a geodetic head of over 15 m fit a check valve
between the pump and the gate valve in order to pro-
tect the pump from water hammering.

6.5 Electrical connection

Electrical connection must be carried out only
by  a  qualified  electrician  in  accordance  with
local regulations.

Follow all safety standards.
The unit must be properly earthed (grounded).

Connect the earthing (grounding) conductor to  the
terminal with the 

marking. 

Compare the  frequency  and  mains  voltage  with  the
name-plate  data  and  connect  the  supply  conductors
to  the  terminals  in  accordance  with  the  appropriate
diagram inside the terminal box cover.

ATTENTION: never allow washers or other
metal parts  to  fall  into  the  internal  cable
opening between the terminal box and stator.

If this occurs, dismantle the motor to recover the
object which has fallen inside.

If the terminal box is provided with an inlet gland, use
a  flexible  power  supply  cord  of  the  H07  RN-F  type
with  section  of  cable    not  less  than  (par.  12.3  TAB
1)..
If  the  terminal  box  is  provided  with  an  inlet  bushing,
connect the power supply cord through a conduit.
For use in swimming pools (not when persons are in
the  pool),  garden  ponds  and  similar  places,  a 

resi-

dual current device 

with IΔN not exceeding 30 mA

must be installed in the supply circuit.
Install  a 

device  for  disconnection  from  the  mains

(switch) with a contact separation of at least 3 mm in
all poles.
With a three-phase motor install an overload protec-
tion with curve D device appropriate for the rated cur-
rent of the pump.

Single-phase  NMPM,

are  supplied  with  a  capacitor

connected  to  the  terminals  and  (for  220-240  V  -  50
Hz) with an incorporated thermal protector.

7 STARTUP AND OPERATION

7.1 Preliminary  checks  before  start-up  of  the

pump

Do not start-up the device in case of damaged parts.

7.2 First starting

ATTENTION: never run the pump dry. 

Start the pump

after filling it completely with liquid.

When  the  pump  is  located  above  the  water  level

(suction  lift  operation)  fill  the  pump  with  water  up  to
suction pipe level through the opening on the strainer
after removing the cover
(fig. 2).

ATTENTION:  for  transportation  the  cover  is  tem-
porarily closed with hexagon nuts.
Replace them with the hand knobs (15.12) located
inside the filter.

When operating with the pump below water level

(inflow under positive suction head), fill the pump by
opening  the  suction  gate  valve  slowly  and  comple-
tely, keeping the delivery gate valve open to release
the air.

With a three-phase motor check that the direction
of  rotation

is  as  shown  by  the  arrow  on  the  pump

casing,  otherwise,  disconnect  electrical  power  and
reverse the connections of two phases.
With  a  suction  lift  operation  it  may  be  necessary  to
wait a few minutes for the pump to prime.
Check  that  the  pump  works  within  its  field  of  perfor-
mance, and that the absorbed current shown on the
name-plate is not exceeded.
Otherwise adjust the delivery gate valve.

7.3 Switch off of the pump

The  appliance  must  be  switch  off  every  time
there are faults. (see troubleshooting).

The  product  is  designed  for  a  continuous  duty,    the
switch  off  is  performed  by  disconnecting  the  power
supply  by  means  the  expected  disconnecting  devi-
ces. (see paragraph "6.5 Electrical connection").

8 MAINTENANCE

Before  any  operations  it's  necessary  to  disconnect
the power supply. 
If required ask to an electrician or to an expert techni-
cian.

Every  maintenance  operations,  cleaning  or
reparation executed with the electrical system
under  voltage,  it  could  cause  serious  injuries
to people.

If  the  supply  cord  is  damaged,  it  must  be
replaced  by  the  manufacturer,  its  service
agent or similarly qualified persons in order to
avoid a hazard.

In case of extraordinary maintenance, or maintenan-
ce  operations  that  require  part-removing,  the  opera-
tor must be a qualified technician able to read sche-
mes and drawings.
It  is  suggest  to    register  all  maintenance  operation
executed. 

During  maintenance  keep  particular  attention
in  order  to  avoid  the  introduction  of  small
external  parts,  that  could  compromise  the
device safety.

OFF

ON

OFF

i

EN

NMP Rev. 16 - Operating Instructions

Pagina 11 / 64

IST NMP Rev16 07_2019_MXS 11_03con gall  28/08/19  08:39  Pagina 11

Summary of Contents for B-NMP 32/12A/A

Page 1: ...ncorporado Sj lv evakuerande poolpumpar med inbyggd silkorg Zelfaanzuigende zwembadpompen met ingebouwd voorfilter NMP ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTIONS Page 8 En...

Page 2: ...atore non deve essere effettuata da bambini senza sorveglianza Non usare l apparecchio in stagni vasche e piscine quando nell acqua si trovano persone Leggere attentamente la sezione installazione dov...

Page 3: ...i divieti sopracitati 2 3 Marcatura Di seguito una copia della targhetta di identificazione presente sull involucro esterno della pompa 3 CARATTERISTICHE TECNICHE 3 1 Dati tecnici Dimensioni di ingomb...

Page 4: ...bientali e dimensioni del luogo di installazione Il cliente deve predisporre il luogo di installazione in modo adeguato alla corretta installazione e in coe renza alle esigenze costruttive della stess...

Page 5: ...l coperchio fig 2 ATTENZIONE per la spedizione il coperchio chiu so provvisoriamente con dadi esagonali Sostituirli con i volantini 15 12 che si trovano all interno del prefiltro Con il livello dell a...

Page 6: ...orpo pompa 8 2 Smontaggio dall impianto Prima dello smontaggio chiudere le saracinesche in aspirazione e mandata 8 3 Smontaggio della pompa Prima dello smontaggio chiudere le saracinesche in aspirazio...

Page 7: ...stituire il motore a Sbloccare la pompa agendo sull intaglio ricavato nella parte posteriore dell albero b Rimuovere i corpi solidi all interno della girante c Sostituire i cuscinetti a Sfiatare l ari...

Page 8: ...ean or maintain it unless they are given supervision Do not use in ponds tanks or swimming pools or where people may enter or come into contact with the water Read carefully the installation section w...

Page 9: ...for failure or accident due to improper use 2 3 Marking The following picture is a copy of the name plate that is on the external case of the pump 3 TECHNICAL FEATURES 3 1 Technical data Dimensions an...

Page 10: ...e dimensions of the device refer to the annex Dimensions paragraph 12 1 Annexes 6 2 Ambient requirements and installation site dimensions The customer has to prepare the installation site in order to...

Page 11: ...s located above the water level suction lift operation fill the pump with water up to suction pipe level through the opening on the strainer after removing the cover fig 2 ATTENTION for transportation...

Page 12: ...sing before dismantling the pump 8 3 Dismantling the pump Close the suction and delivery gate valves and drain the pump casing before dismantling the pump For dismantling and reassembly see constructi...

Page 13: ...scosity of the liquid pumped 4g Incorrect direction of rotation 5a Worn bearings 5b Unbalanced power supply 6a The mechanical seal has functioned when dry or has stuck 6b Mechanical seal scored by pre...

Page 14: ...rs das Ger t zu Reinigen und zu Warten Kinder d rfen niemals das Ger t Reinigen oder Warten es sei denn sie befinden sich unter strenger qualifi zierter Aufsicht und Anleitung Das Ger t darf nicht ein...

Page 15: ...zu anderen unzul ssigen Zwecken oder unter in diesem Handbuch nicht vorgesehenen Bedingungen ist strengstens verboten Die Fehlanwendung des Produktes verringert seine Sicherheits und Effizienzmerkmale...

Page 16: ...s sich die Verpackung beim Transport nicht frei bewegen kann Die Mittel zum Transport des verpackten Ger tes m ssen f r die Abmessungen und das Gewicht des gekauften Produktes geeignet sein siehe Kap...

Page 17: ...stand der Kontakte von mindestens 3 mm zu instal lieren Bei Dreiphasen Drehstrommotoren ist ein Motorschutzschalter mit Kurve D gem der Stromaufnahme laut Typenschild vorzusehen Die Einphasen Wechsel...

Page 18: ...nd gesundheitsgef hrdende Ausstr mungsgefahr Korrosionsgefahr bei stehendem Wasser sowie bei Temperaturerh hung oder pH Wert Minderung Wird die Pumpe nicht eingesetzt so mu sie bei Frostgefahr vollst...

Page 19: ...Erh hte Viskosit t des F rdermediums g Falsche Drehrichtung a Motolager defekt b Fehler der Spannungsversorgung a Defekt infolge von Trockenlauf oder verkleben der Gleitfl chen b Gleitfl chen duch ab...

Page 20: ...ar des enfants sans surveillance Ne pas utiliser l appareil dans des tangs des cuves ou des piscines quand des personnes sont dans l eau Lisez attentivement la section d installa tion qui nonce La pre...

Page 21: ...ns pr sent es ci dessus 2 3 Marquage Ci dessous voici une copie d une plaquette d identifi cation situ e sur le corps ext rieur de la pompe 3 CARACT RISTIQUES TECHNIQUES 3 1 Donn es techniques Dimensi...

Page 22: ...riels qui pourraient d t riorer la pompe Si le produit emball p se plus de 25 Kg il doit tre soulev par deux personnes ensemble voir Chap 12 1 dimensions encombrement 6 INSTALLATION 6 1 Dimensions d...

Page 23: ...2 ATTENTION pour le transport le couvercle est ferm temporairement par des crous hexagonaux Les rem placer avec les volants 15 12 qui se trouvent l int rieur du filtre Avec le niveau de l eau c te as...

Page 24: ...rmer les vannes d a spiration et de refoulement 8 3 D montage de pompe Avant le d sassemblage fermer les vannes d aspiration et de refoulement et vider le corps de pompe Pour le d montage et le remont...

Page 25: ...e pour le type d application d Suintement initial l ger pendant le remplissage ou au premier d marrage 11 DYSFONCTIONNEMENTS Attention Couper l alimentation lectrique avant de r aliser toute op ration...

Page 26: ...dos por ni os sin vigilancia No utilizar el dispositivo en estanques tanques y piscinas cuando hay gente en el agua Lea cuidadosamente la secci n de instalaci n que establece La pression estructural d...

Page 27: ...las prohibiciones mencionadas antes 2 3 Marca A continuaci n se muestra una copia de la tarjeta de identificaci n presente en el exterior de la bomba 3 CARACTER STICAS T CNICAS 3 1 Datos t cnicos Dime...

Page 28: ...ientales y dimensiones del lugar de instalaci n El cliente tiene que preparar el lugar de instalaci n de manera adecuada para aseguarar la instalaci n correcta y de acuerdo con los requisitos de const...

Page 29: ...a bomba con agua hasta el nivel de la boca de aspira ci n a trav s de la apertura sobre el filtro extrayendo la tapa v ase cap 12 2 Fig 2 ATENCI N Para la expedici n la tapa esta cerrada provisionalme...

Page 30: ...es del desmontaje cierre las compuertas en aspi raci n y descarga 8 3 Desmontaje bomba Antes del desmontaje cerrar las compuertas de aspi raci n y de impulsi n y vaciar el cuerpo bomba Para el desmont...

Page 31: ...de gases en el agua f Viscosidad excesiva del l quido bombeado g Sentido de rotaci n equivocado a Cojinetes desgastados b Alimentaci n el ctrica desequilibrada a El sello mec nico ha funcionado en sec...

Page 32: ...e leka med apparaten Reng ring och underh ll av apparaten m ste utf ras av anv ndaren Reng ring och underh ll f r inte utf ras barn utan en vuxens tillsyn Anv nd inte apparaten i dammar bas s nger ell...

Page 33: ...rsummelse att iaktta ovan n mn da f rbud 2 3 M rkning Nedan f ljer en kopia av m rkskylten som r place rad p pumpens yttre h lje 3 TEKNISKA EGENSKAPER 3 1 Tekniska data Totalm tt och vikt kap 12 1 No...

Page 34: ...1 ver totalm tt 6 INSTALLATION 6 1 Totalm tt F r apparatens totalm tt se bilagan Totalm tt kap 12 1 BILAGOR 6 2 Milj krav och m tt p installationsplatsen Kunden ska f rbereda installationsplatsen p l...

Page 35: ...en Vid en trefasinstallation kontrollera att rotation sriktningen st mmer med pilen p pumphuset om inte bryt all elstr m och skifta tv av elfaserna till elmotorn Vid sugande funktion kan det bli m jli...

Page 36: ...t muttrarna 14 28 avl gsnas motorn komplett med pumphjul kan d tas ut bak t 8 4 Pumpar med IP55 klassificering Special kon struktion F r att f rs kra IP55 klassificering r det n dv ndigt att kontrolle...

Page 37: ...rskriden viskositet p v tskan g Felaktig rotationsriktning a Slitna Lager b Ostabil sp nningsmatning a Den mekaniska axelt tningen har torrk rts eller varit blockerad b Axelt tningen skadad av slitand...

Page 38: ...appa raat nooit schoonmaken of onderhouden tenzij ze onder toezicht staan Geen gebruik in vijvers tanks of zwem baden of waar personen binnentreden of in contact komen met het water Lees uitvoerig het...

Page 39: ...n niet verantwoordelijk worden gehouden voor defecten of ongelukken die te wijten zijn aan het niet in acht nemen van de hierbo ven omschreven verboden 2 3 Markering Hieronder staat een kopie van het...

Page 40: ...orzichtig want er mag niet tegenaan gestoten worden Er mag geen ander materiaal op de verpakking geplaatst worden om te vermijden de pomp beschadigd zou worden Wanneer het gewicht meer dan 25 kg bedra...

Page 41: ...ijderd zie par 12 2 fig 2 ATTENTIE voor het transport is het deksel tijdelijk gemonteerd met moeren Vervang deze door de handmoeren 15 12 te vinden in het filter Als men werkt bij een positieve voordr...

Page 42: ...montage van de installatie Sluit de schuiven van aanzuiging en uitlaat alvorens de demontage uit te voeren 8 3 Demontage Sluit de zuig en perskleppen en tap het pomphuis af voordat men de pomp demonte...

Page 43: ...chting a Versleten lagers b Wisselende stroom voeding a De mech seal heeft gefunctioneerd echter droogloop of loopvlakken stuk b Loopvlakken zijn ingelopen door aanwezigheid van abrassieve delen in he...

Page 44: ...LPEDA S p A 1 44 2 45 3 45 4 45 5 46 6 46 7 47 8 47 9 48 10 48 10 1 49 11 49 12 61 12 1 61 12 2 62 12 2 63 64 1 Calpeda SpA 2 3 8 3 1 6 5 6 5 1 1 E E i OFF ON IST NMP Rev16 07_2019_MXS 11_03con gall 2...

Page 45: ...V 3 50 60 Hz E 2 2 kW 70 dB A 3 11 kW 85 dB A 60 2 2 kW 40 3 7 5 kW 20 9 2 11 kW 60 m 6 bar PN Pa Hmax Pa 3 2 40 C 4 4 1 i XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y...

Page 46: ...4 NMP Rev 16 GR CALPEDA S p A 4 2 4 3 4 4 4 5 5 12 1 5 1 25 kg 12 1 6 6 1 12 1 6 2 3 2 6 3 12 2 1 6 4 NMP vx 6 4 1 1 5 m s 3 m s 6 4 2 i i i IST NMP Rev16 07_2019_MXS 11_03con gall 28 08 19 08 39 Pagi...

Page 47: ...47 64 NMP Rev 16 GR 6 4 3 15m 6 5 L 07 RN F 12 3 TAB 1 30mA 3 mm D NMPM 220 240V 7 7 1 7 2 12 2 2 15 12 2 7 3 OFF 6 5 8 OFF OFF ON IST NMP Rev16 07_2019_MXS 11_03con gall 28 08 19 08 39 Pagina 47...

Page 48: ...MP Rev 16 GR CAL PEDA SpA CALPEDA SpA 8 1 8 2 8 3 14 28 8 4 IP 55 IP 55 LOCTITE 510 9 2012 19 EU WEEE 10 10 1 CALPEDA S p A OFF OFF i i OFF OFF IST NMP Rev16 07_2019_MXS 11_03con gall 28 08 19 08 39 P...

Page 49: ...36 00 36 50 46 00 70 20 70 21 73 00 76 00 76 04 76 16 76 20 76 54 78 00 81 00 82 00 82 04 82 08 88 00 88 04 90 00 90 04 94 00 98 00 98 04 98 08 11 OFF 1 2 3 4 5 6 a b c d e f a b c a b c d a b c d e f...

Page 50: ...LPEDA S P A 1 50 2 51 3 51 4 51 5 52 6 52 7 53 8 53 9 54 10 54 10 2 55 11 55 12 61 12 1 61 12 2 62 12 4 63 64 1 Calpeda S p A 2 3 CE 8 3 1 6 5 6 5 1 1 i OFF ON IST NMP Rev16 07_2019_MXS 11_03con gall...

Page 51: ...80V 3 50 60 Hz 2 2 kW 70 dB A 3 11 kW 85 dB A 60 2 2 kW 40 3 7 5 kW 20 9 2 11 kW 60 6 PN Pa Hmax Pa 3 2 40 4 4 1 i i XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50H...

Page 52: ...C 52 64 NMP Rev 16 RU Calpeda S p A 4 2 4 3 4 4 4 5 5 12 1 5 1 25 12 1 6 6 1 12 1 6 2 3 2 6 3 12 1 1 6 4 NMP 6 4 1 1 5 i i IST NMP Rev16 07_2019_MXS 11_03con gall 28 08 19 08 39 Pagina 52...

Page 53: ...C 53 64 NMP Rev 16 RU 6 4 2 6 4 3 15 6 5 07 RN F 12 3 TAB 1 I N 30 mA 3 D NMPM 50 220 240 7 7 1 7 2 12 2 2 15 12 7 3 6 5 8 ON OFF OFF IST NMP Rev16 07_2019_MXS 11_03con gall 28 08 19 08 39 Pagina 53...

Page 54: ...ev 16 RU Calpeda S p A Calpeda S p A 8 1 12 3 3 8 2 8 3 14 28 8 4 IP55 IP55 LOCTITE 510 9 2012 19 EU WEEE 10 10 1 Calpeda S p A OFF OFF OFF i i OFF IST NMP Rev16 07_2019_MXS 11_03con gall 28 08 19 08...

Page 55: ...0 28 00 28 04 28 20 32 00 32 30 32 32 32 33 36 00 36 50 46 00 70 20 70 21 73 00 76 00 76 04 76 16 76 20 76 54 78 00 81 00 82 00 82 04 82 08 88 00 88 04 90 00 90 04 94 00 98 00 98 04 98 08 11 OFF 1 2 3...

Page 56: ...10 59 10 2 59 11 60 12 61 12 1 61 12 2 62 12 4 63 64 1 CALPEDA S P A 2 3 CE 8 3 1 6 5 6 5 1 1 1 2 CALPEDA S P A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 i...

Page 57: ...from 9 2 to 11 kW 60 m 6 bar PN Pa Hmax Pa 3 2 40 4 4 1 CALPEDA S P A 4 2 4 3 4 4 4 5 5 12 1 5 1 25 12 1 i XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X...

Page 58: ...6 6 1 12 1 6 2 3 2 6 3 12 2 1 6 4 NMP 6 4 1 1 5m s 3m s 6 4 2 6 4 3 15M 6 5 H07RN F 12 3 30 3mm D NNMPM 220 240V 50Hz 7 7 1 7 2 2 7 3 6 5 8 OFF OFF i ON IST NMP Rev16 07_2019_MXS 11_03con gall 28 08 1...

Page 59: ...14 00 14 12 14 20 O 14 24 14 28 14 46 15 00 15 04 O 15 08 15 12 15 50 28 00 28 04 28 20 32 00 32 30 32 32 32 33 36 00 36 50 46 00 70 20 70 21 73 00 76 00 76 04 76 16 76 20 76 54 78 00 81 00 82 00 82 0...

Page 60: ...1c 1d 1e 1f 2a 2b 3c 3a 3b 3c 3d 4a 4b 4c 4d 4e 4f 4g 5a 5b 6a 6b 6c 6d 1a 1b 1c 1d a c 1e 2 1f 2a 2b 2c 3a 3b 3c 3d 2b 4a 4b 4c 4d 4e 4f 4g 5a 5b 6a 6b 6c 6a 6b 6c 6d 6a 6b 6c IST NMP Rev16 07_2019_...

Page 61: ...12 B B B B G 3 G 3 320 717 748 908 360 80 298 320 345 470 125 95 280 212 60 49 43 65 14 298 279 458 858 345 43 408 15 TIPO l1 l2 106 99 120 117 165 164 mm B NM NM NM NM NM NM NM NM NM NM NM NM NM B B...

Page 62: ...ement de la pompe Vidange Entr e d air Llenado Elevaci n de la bomba Vaciado Entrada aire Fyllning Lyft Dr nering Luftinsl pp Vullen Heffen van de pomp Aftappen Luchtinlaat 4 93 O49 12 3 Sezione minim...

Page 63: ...2 1 3 94 082 2 NMP 32 12SE AE DE FE NMP 52 12FE GE HE NMP 50 12DE NMP 65 16DE EE FE NMP 50 12DE NMP 65 16AE CE DE EE FE Solo nei tipi Only for types Nur f r Baugr en Seulement pour les types Solo en l...

Page 64: ...d bestemmelserne i Direktiv 2006 42 EC 2009 125 EC 2011 65 EU 2014 30 EU 2014 35 EU og er i overensstemmelse med de heri indeholdte standarder Kommissionens forordning nr 640 2009 NL CONFORMITEITSVERK...

Reviews: