Operation:
The CALMAG YORKSHIRE LTD CALULTRA system comes with a feature laden control system that
incorporates both the lamp driver (ballast) and control features in one modular panel. CAUTION: Prior to
performing any maintenance on your UV system, you must always disconnect the power (DO NOT SIMPLY
USE THE SWITCH ON THE FRONT OF THE CONTROLLER).
CALULTRA
Control Panel
The control panel features a power factor corrected and constant current lamp
driver. Simplistic in operation, the panel features an LED display for remaining
lamp life, total running hours, audible and visual lamp failure, remote on and
solenoid ready. When the UV lamp(s) is/are on, the second LED box will read
“ON”. When the UV lamp(s) is/are not on, the LED box will read “OFF” and an
audible alarm will sound. Please Note: If the LED reads “OFF” and the alarm is
sounding then the water from the system should NOT be consumed. If any
water does pass through the UV system during this period, please follow the
disinfection procedure as outlined in this manual before the water is
consumed. It should also be noted that on the CALULTRA system even though
this system does have a visual and audible warning built into the controls, the
LED reading “ON” does not necessarily indicate that the water coming from this
system is in fact potable (safe to drink). This system does not measure the level
of disinfection; it simply measures the “ON-‐OFF” status of the lamp. For a
constant reassurance of safe water quality you should consider the CALULTRA
upgrade with a UV sensor (you can also add the optional RS-‐RUV sensor on all
CALULTRA systems). Please have your water checked for microbiological
contaminants on a regular basis.
CALULTRA 3-‐Position Switch
The control panel features a 3-‐position user-‐selectable switch. This switch is NOT a power switch and it
should be noted that once the control panel is plugged into an electrical outlet, the unit is powered and
considered “ON”. The switch functions as follows:
“ON” position – Power is supplied to the lamp(s) and the controller will read
“ON” on the lower LED display on units without a UV sensor installed and will
read the intensity (or UV output) on units with a UV sensor installed. Please
note that when first starting the lamp(s), the system will cycle through a
declining numerical sequence while the lamp(s) reaches full power.
“OFF” position – Power is NOT supplied to the lamp(s) and the lamp(s) will be
off. The controller will read “OFF” on the lower LED display.
Page
14