CALMAG YORKSHIRE LIMITED EQUIPMENT
SPECIFICATIONS
CalUltra commercial ultra violet systems
MODEL
CalUltra 530
CalUltra 662
CalUltra 1500
CalUltra 2400
Flow Rate @ 30 mJ/cm
2
@ 95% UVT
140 GPM
175 GPM
400 GPM
625 GPM
530 lpm
662 lpm
1500 lpm
2400 lpm
31.8 m
3
/hr.
39.7 m
3
/hr.
90 m
3
/hr.
144 m
3
/hr.
Alternative flow @
16mJ/cm
2
@ 95% UVT
263 GPM
327 GPM
758 GPM
1170 GPM
996 lpm
1240 lpm
2870 lpm
4420 lpm
59.7 m
3
/hr.
74.3
3
/hr.
87.7 m
3
/hr.
175.4
3
/hr.
Port Size
3"
4"
4" flanged
6" flanged
Electrical
230-‐240V./50-‐60Hz.
Plug Type
British Standard, BS1363
Lamp Watts
344
414
828
1242
Power (watts)
360
430
900
1340
Replacement Lamp
BULB-‐B530 (2)
BULB-‐B662 (2)
BULB-‐B1500 (4)
BULB-‐B2400 (6)
Replacement Sleeve
SLEEVE-‐QS530 (2) SLEEVE-‐QS662 (2)
SLEEVE-‐QS1500
(4)
SLEEVE-‐QS2400 (6)
Chamber Dimensions
6 x 40.6 x 7.9”
(15 x 103 x 20
cm)
6 x 46.8 x 7.9"
(15 x 119 x 20
cm)
Contact Calmag
Contact Calmag
Chamber Material
Polished 304 Stainless Steel, A249 Pressure Rated Tubing
Controller Dimensions
15.8 x 11.8 x 6.3” (40.0 x 30.0 x 16.0 cm) Contact Calmag Contact Calmag
Maximum Operating Pressure
10.3 bar (150 psi)
Optimum Water Temperature
2-‐60° C (36-‐148° F)
UV Monitor Port
(upgradeability)
Yes
Yes
Remote ON & Dry Contacts
Yes
4-‐20 mA Output
Yes
Lamp Age Counter
Yes
Visual Lamp-‐Out Indicator &
Audible Lamp-‐Out Alarm
Yes