CALMAG YORKSHIRE LIMITED EQUIPMENT
SPECIFICATIONS
CalUltra commercial ultra violet systems
MODEL
CalUltra 132
CalUltra 220
CalUltra 322
CalUltra 416
Flow Rate @ 30 mJ/cm
2
@ 95% UVT
35 GPM
58 GPM
85 GPM
110 GPM
132 lpm
220 lpm
322 lpm
416 lpm
8 m
3
/hr.
13.2 m
3
/hr.
19.3 m
3
/hr.
25 m
3
/hr.
Alternative flow @
16mJ/cm
2
@ 95% UVT
66 GPM
109 GPM
167 GPM
207 GPM
250 lpm
413 lpm
632 lpm
784 lpm
15 m
3
/hr.
24.8 m
3
/hr.
37.9 m
3
/hr.
47 m
3
/hr.
Port Size
1½"
2"
2"
2½"
Electrical
230-‐240V./50-‐60Hz.
Plug Type
British Standard, BS1363
Lamp Watts
104
152
207
304
Power (watts)
120
170
220
320
Replacement Lamp
BULB-‐B132
BULB-‐B220
BULB-‐B322
BULB-‐B416 (2)
Replacement Sleeve
SLEEVE-‐QS132
SLEEVE-‐QS220
SLEEVE-‐QS322
SLEEVE-‐QS416 (2)
Chamber Dimensions
4 x 27.2 x 5.6”
(10 x 69 x 14 cm)
4 x 35.8 x 5.6"
(10 x 91 x 14 cm)
4 x 46.8 x 5.6"
(10 x 119 x 14 cm)
6 x 35.8 x 7.9"
(15 x 91 x 20 cm)
Chamber Material
Polished 304 Stainless Steel, A249 Pressure Rated Tubing
Controller Dimensions
11.8 x 7.9 x 6.3" (30.0 x 20.0 x 16.0 cm) 15.8 x 11.8
x 6.3”
Maximum Operating Pressure
10.3 bar (150 psi)
Optimum Water Temperature
2-‐60° C (36-‐148° F)
UV Monitor Port
(upgradeability)
Yes
Yes
Remote ON & Dry Contacts
Yes
4-‐20 mA Output
Yes
Lamp Age Counter
Yes
Visual Lamp-‐Out Indicator &
Audible Lamp-‐Out Alarm
Yes
Page
20
Summary of Contents for CALULTRA 132