32
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
2.
Thread the cables through appropriately sized conduit. Leave just enough extra length of
all cables to secure each cable type to its intended termination point.
Note:
In a typical configuration, the Model 560 ONT can accommodate (4) voice (RJ-
11), (1) analog video (F-Connector) and (4) data (RJ-45) lines. Make sure the conduit
chosen is big enough to accommodate a large bundle of cables. Knock-outs in the
bottom of the chassis are variable in size - choose the proper one for your application.
3.
Secure the conduit (if present) to the ONT unit using the knock-outs provided.
4.
Connect the telephone lines from the subscriber to the colored binding posts on the
bottom right hand side of the housing.
5.
Connect coaxial cable from the subscribers to the RG-59 “F” connectors on the video
board.
6.
Connect the Ethernet data cables (RJ-45) from the subscribers to the Ethernet jack
located on the MEM of the Model 560
ONT.
(2) Expansion
Module Slot
(4) RJ-11 Telephony Ou t
(4) RJ-45 Ethernet Out
(High Speed Data/SVS)
(1) SC-APC Optical
Input (GPON Fiber)
(1) F-Connector Video
Out (To Subscriber o r
Expansion Module)
5235
Bottom Edge of MEM
© 2001-2007 Calix. All Rights Reserved.