58
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© 2001-2007 Calix. All Rights Reserved.
Supply Power
Battery
AC Voltage
Range
85 - 264 Vac
Source
UPS mounted indoors
DC Voltage
Range
-46 to -52 Vdc
Power Termination
30 feet standard. 40 feet
available as accessory.
DC Voltage
Supply
-50 Vdc
Output Voltage
50 Vdc
Maximum Watts
25 watts
Capacity
8 hours (Life-line compliant)
Maximum Amps
.5 amps
Maximum BTU
Output per Hour
86 BTUs
Input Cabling
Flexible AC power cord
Mechanical
Telephony Interface
Height
20 inches (50.8 cm)
Interface
GR-909 Single Party
message Telephone
Service with On-hook
transmission, loops start
POTS with Customer and
Class feature support.
Width
16.2 inches (41 cm)
Maximum RENs per line
5
Depth
4.75 inches (12.1 cm)
Maximum RENs per unit 20
Installed Height
(recommended)
50 - 60 inches (1.3 -
1.5 M)
Subscriber Physical
Connection
22 or 24 AWG twisted pair
to binding posts. Premises
isolating RJ-11 test jack
(one per binding post)
Binding Posts
12. Additional binding posts
supported via external
connection.
Number of Lines
4 as standard.
Expansion Lines
16. Requires the addition of
(2) Octal UVG Expansion
Modules
Drop Length
Up to 500 feet (152 M)