2

 

PRODUCT SPECS

 

Voltage Input

110V 

Maximum output current

15AM

Fuse: AC110V 15AM 

Remote control distance

  Open space >150 Feet (50 meters) 

 
 
 
 

WARNING

 

To reduce the risk of INJURY or DEATH: 
 

 

Never let children operate or play with gate control, keep remote control 
away from children. 

 

ALWAYS keep people and objects away from gate. NO ONE SHOULD CROSS 
THE PATH OF MOVING GATE. 

 

Test gate operator monthly. The gate MUST reverse in contact with a rigid 
object of reverse when an object activates the non-contact sensors. After 
adjusting the force or limit of travel, reset gate operator. Failure to adjust 
and  reset  the  gate  operator  properly  can  increase  the  risk  of  INJURY  or 
DEATH. 

 

Use the emergency release ONLY when gate is not moving. 

 

KEEP  GATE  PROPERLY  MAINTAINED.  Read  owner’s  manual.  Having  a 
qualified service person make repairs to gate hardware. 

 

The  entrance  is  for  vehicles  ONLY.  Pedestrians  MUST  use  separate 
entrance.   

 

SAVE THESE INSTRUCTIONS. 

 

 
 
 
 

Summary of Contents for CM-5-ACFP

Page 1: ...1...

Page 2: ...st gate operator monthly The gate MUST reverse in contact with a rigid object of reverse when an object activates the non contact sensors After adjusting the force or limit of travel reset gate operat...

Page 3: ...nstallation of Base 1 Lay out position of 6 Anchors by measuring clearance between anchors and inside edge of gate Figure 1 2 Install underground conduits in area for conduits Figure 2 Figure 1 Figure...

Page 4: ...4 Installation Barrier distance Figure 3 Figure 4...

Page 5: ...5 Position of gate and operator Two options of chain connection Figure 5 Front Mount Figure6 Rear Mount...

Page 6: ...Welding Bracket of Chain Figure 7 Correct connection of chain Figure 8 Figure 8 Follow the correct way to install chain Incorrect installation will cause malfunction of operator and potential damages...

Page 7: ...wires power wires MUST have minimum capacity for 25 Am current 2 All operators MUST properly grounded in order to prevent electrical charge Must use dedicated circuit for power supply 3 When power co...

Page 8: ...ghtly to the right until it was locked in down Position 3 Hold and push gate to desired direction B Reset pedal Only when operator has No reaction while using remote control 1 Push pedal downward from...

Page 9: ...9 Entrapment protection Safety and Exit loop Figure 11...

Page 10: ...10 Control Board lay out Figure 12...

Page 11: ...11 Gate Travel Limit Adjustment Figure 13 Turn up or down of both wheels to adjust distance between them making gate stop at the position desired...

Page 12: ...STUDY key and hold for 8 seconds watching light state flashing solid flashing setting done All existing Self study codes have been removed Numeric Mode A First to turn SW9 key to ON position now contr...

Page 13: ...gate When switch ON The LOCK in Control board Left edge Figure 12 will be available to output 115 V power 5 1 PASS Anti tailgating system It corresponds to underground safety loop when ON selected Onc...

Page 14: ...rol instruction to connect power Common wire connected to Common pole Signal wire connected to OPEN or CLOSE pole Use of External Receiver Figure 17 Ports on external receiver are marked as 1 2 and 3...

Page 15: ...ave control Board then connect DATA and DATA accordingly 3 M LINK light turn to solid bright Use Reversing Device Figure 19 1 CLOSE ERD when closing gate increase decrease amount of force by turning k...

Page 16: ...l delay closing 1 Choose time delay to activate operator between 0 6 seconds by turning knob on DELAY B Timer automatic delay closing 1 On DIP switch Set key TIMER to ON position Figure 15 2 Adjust kn...