background image

 
 
 

12

 

Use Remote Control 

Device

 

Figure 12

 

There are two modes to set Remote Control: Self-study Mode& Numeric Mode   
 

 

  Self-study code may be set up to 60 groups.   
 

A.

 

  Self-study mode corresponds to receiver in control board. Press and hold STUDY key 

for  3  seconds  until  flashing  light  turn  to  solid  bright,  press  any key on  Remote  Control  until 
STUDY light turn to flashing again, setting done. Repeat above if additional code needed.   

B.

 

Existing Codes removal. Press STUDY key and hold for 8 seconds, watching light state: 

flashing-solid-flashing, setting done. All existing Self-study codes have been removed. 

 

 

Numeric Mode 
 

A.

 

First to turn SW9 key to ON position, now control board activated. 

B.

 

Make a combination of code. On SW8, Set an 8-digi combination to match identical 8-digi 

combination on  Remote Control. Note:  each  switch could be placed on up, middle and low 
position. No limit of groups of combinations. 
C.

 

On switch SW10, KEY 1 and KEY 2 are used for 2-buttom model of remote controls. Note: if 

KEY 1 code was set corresponding with BUTTON ONE on remote control, then KEY 1 will NOT 
work with BUTTON TWO on remote control. 

 

Summary of Contents for CM-5-ACFP

Page 1: ...1...

Page 2: ...st gate operator monthly The gate MUST reverse in contact with a rigid object of reverse when an object activates the non contact sensors After adjusting the force or limit of travel reset gate operat...

Page 3: ...nstallation of Base 1 Lay out position of 6 Anchors by measuring clearance between anchors and inside edge of gate Figure 1 2 Install underground conduits in area for conduits Figure 2 Figure 1 Figure...

Page 4: ...4 Installation Barrier distance Figure 3 Figure 4...

Page 5: ...5 Position of gate and operator Two options of chain connection Figure 5 Front Mount Figure6 Rear Mount...

Page 6: ...Welding Bracket of Chain Figure 7 Correct connection of chain Figure 8 Figure 8 Follow the correct way to install chain Incorrect installation will cause malfunction of operator and potential damages...

Page 7: ...wires power wires MUST have minimum capacity for 25 Am current 2 All operators MUST properly grounded in order to prevent electrical charge Must use dedicated circuit for power supply 3 When power co...

Page 8: ...ghtly to the right until it was locked in down Position 3 Hold and push gate to desired direction B Reset pedal Only when operator has No reaction while using remote control 1 Push pedal downward from...

Page 9: ...9 Entrapment protection Safety and Exit loop Figure 11...

Page 10: ...10 Control Board lay out Figure 12...

Page 11: ...11 Gate Travel Limit Adjustment Figure 13 Turn up or down of both wheels to adjust distance between them making gate stop at the position desired...

Page 12: ...STUDY key and hold for 8 seconds watching light state flashing solid flashing setting done All existing Self study codes have been removed Numeric Mode A First to turn SW9 key to ON position now contr...

Page 13: ...gate When switch ON The LOCK in Control board Left edge Figure 12 will be available to output 115 V power 5 1 PASS Anti tailgating system It corresponds to underground safety loop when ON selected Onc...

Page 14: ...rol instruction to connect power Common wire connected to Common pole Signal wire connected to OPEN or CLOSE pole Use of External Receiver Figure 17 Ports on external receiver are marked as 1 2 and 3...

Page 15: ...ave control Board then connect DATA and DATA accordingly 3 M LINK light turn to solid bright Use Reversing Device Figure 19 1 CLOSE ERD when closing gate increase decrease amount of force by turning k...

Page 16: ...l delay closing 1 Choose time delay to activate operator between 0 6 seconds by turning knob on DELAY B Timer automatic delay closing 1 On DIP switch Set key TIMER to ON position Figure 15 2 Adjust kn...