![Calimet CM-5-ACFP Instructions Manual Download Page 8](http://html1.mh-extra.com/html/calimet/cm-5-acfp/cm-5-acfp_instructions-manual_3441800008.webp)
8
EMERGENCY RELEASE
Figure 10
A. Emergency Release of gate
1.
Disconnect power.
2.
Push Release pedal downward and move slightly to the right until it was locked in down
Position.
3.
Hold and push gate to desired direction.
B. Reset pedal (Only when operator has No reaction while using remote control)
1.
Push pedal downward from locked position and slightly move to the left, unlocked
Pedal.
2.
Allow Pedal rise up to reset position and release pedal.