- Insert the day turning the knob

- Press the knob to confirm the day set

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

- Enter the month turning the knob

- Press the knob to confirm the month set

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

- Enter the year turning the knob

- Press the knob to confirm the year set

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

During the date and time configuration, the device performs the full 

scale and zero acquisition, and after the year has been confirmed, 

the device enters in water mixing mode and the following screen is 

displayed.

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

IMPORTANT: Completing the date and time setting, the 

device starts the water mixing function with the default 

parameters (table on page 8). If the probe T2 is not 

connected, the relevant alarm is triggered. If the initial 

parameters have not been confirmed, the device does not 

perform the disinfection. 

Operating status

During the operation of the device, the following work states can be 

displayed:

1 - Reached setpoint

2 - Adjustment in progress

3 - Disinfection in progress

 

4 - Thermal shock in progress

5 - Zero and full scale acquisition

The LCD display indicates the device status, as shown in the following 

screens.

1 - Reached setpoint:

Water mixing with set point reached. Motor stopped.

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

2 - Adjustment in progress:

a)  Water mixing with temperature rise. Motor opening indicated by the 

following symbols.

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

b)  Water mixing with temperature decrease. Closed motor indicated by 

the following symbols.

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

c)  Reaching the closing limit switch and T1> TSET. The mixer can 

not reach the set value, even though it is in the maximum closing 

position; therefore the following symbol is displayed.

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

3

Summary of Contents for LEGIOMIX 6000 series

Page 1: ...and default values Display menu Programming Menu Installer Menu Alarm management General diaphragm 2 3 6 8 7 10 11 14 PROGRAMMING MANUAL Copyright 2018 Caleffi H0004567 01 www caleffi com Disinfection...

Page 2: ...ved It is recommended to refer to the alarm section in this manual For correct battery installation see the Installation and commissioning manual supplied in the package When the battery checks are co...

Page 3: ...evice does not perform the disinfection Operating status During the operation of the device the following work states can be displayed 1 Reached setpoint 2 Adjustment in progress 3 Disinfection in pro...

Page 4: ...rts are in orange b Disinfection in progress with control on return probe T2 see table on page 5 In this mode the device performs thermal disinfection which consists in raising the mixed water tempera...

Page 5: ...be T1 d2 Disinfection performed at the minimum disinfection temperature diS C Disinfection check performed on probe T1 Disinfection type with recirculation probe T2 enabled Disinfection Code Descripti...

Page 6: ...set tHi diS or with the manual opening of the contact Manual activation through button Automatic end The disinfection status ends as soon as the minimum disinfection time tmin diS is exceeded or withi...

Page 7: ...Reset alarms control Additionally the zero acquisition mode is activated whenever an electric supply failure occurs for at least 60 minutes and at the outlet from any disinfection thermal shock It is...

Page 8: ...om 00 to 99 17 14 Time format selection 12H 24H 24H 15 Hours minutes setting 0 23 hours 0 59 minutes 00 00 16 Daylight saving time setting YES on NO off On 17 Disinfection program change d1 d2 d2 18 T...

Page 9: ...hatever status the appliance is in it is always possible to navigate around the various menus to read and change the various settings The general menu structure is as follows Display menu Press the kn...

Page 10: ...or the day set is displayed the segment below the number indicates its activation Maximum time within which it is possible to perform the disinfection Maximum flow temperature limit it is a system pro...

Page 11: ...uring which the temperature must remain above the set temperature for the thermal shock Setting the maximum time available within which it is possible to perform the thermal shock RESET Control to res...

Page 12: ...x time bands that can be set for recirculation OUT2 activation 1 02 00 and 05 59 4 14 00 and 17 59 2 06 00 and 09 59 5 18 00 and 21 59 3 10 00 and 13 59 6 22 00 and 01 59 Installer Menu password chang...

Page 13: ...of the valve Perform with closed shut off valves The number of times the error has occurred appears in the top right of the screen To delete the alarms from the sub menu use the Reset Alarms Installe...

Page 14: ...F RESETTING BLOCKING ALARM The device resumes its operation when the probe T1 returns to the set value Alarm management To make it easier to resolve any functional faults that occur after installation...

Page 15: ...er mixing status the first successful disinfection clears the alarm condition but records it in the log of the last failed disinfections the display shows the symbol Manual YES it is also recorded in...

Page 16: ...failure for more than 60 minutes NON BLOCKING ALARM When the electric supply is restored it resumes normal operation after performing the zero acquisition AL08 FAULTY FLOW PROBE SELF RESETTING BLOCKIN...

Page 17: ...NC Closed OUT2 Closed OUT3 Open The device can only perform the water mixing while maintaining the alarm active YES PROBE T2 NOT CONNECTED OR DAMAGED Check that the probe is present and correctly con...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Reviews: