Technical specifications

Meter

Display: 

alphanumeric with white backlighting

Minimum flow rate: 

300 l/h 

Maximum flow rate: 

1400 l/h

Maximum error: 

±10%

Units of measurement available: 

l/h, l/min, GPM

Mediums: 

water, glycol solutions (up to 50%)

Weight: 

220 g

Electric supply:

internal 9V NiMh battery

Battery charge

Electric supply voltage:

230 V~50 Hz

Power consumption (max):

6 W

Dimensions

User Interface

1) Display showing flow rate 

2) “ON/OFF” button 

3) “Light” button 

4) “Menu” button

5) “Battery” button

6) Sensor connection socket

7) Battery charger connection socket

Switching on and taking measurements

When the device is switched on, an ID string is shown.
On switching the device on using the ON/OFF button, just press the “Menu” or “Battery” buttons to switch to measurement mode, where the current

flow rate read by the sensor is displayed. The sensor must be connected to the device in order to take a measurement.

When measurement is underway, the following appears on the display:

Q  =  610  [ l / h]

The flow rate symbol is shown followed by a number and the unit of measurement in square brackets. The type of medium is shown on the

second line of the display.

If the flow rate measured is too low (less than 300 l/h), if the sensor is not connected or inserted properly, the device will not be able to measure

correctly and a flow rate of 0 will be shown.

The  LCD  display  shows  flow  rate  during  measurement,

configuration menus and other information needed for the correct

use of the device.
To switch on the device, just press and hold the 

● 

on button until

words appear on the display. To switch the device off, just press

and hold the on button 

● 

until all words on the display disappear.

If  no  keys  are  pressed  for  4  minutes,  the  device  automatically

switches off even if the sensor is still connected: this prolongs the

life of the internal battery.

To extend battery life, a system has been included that switches

the device off after the Vortex sensor cable has been connected or

disconnected. 
Pressing the “Light” 

button switches on or off the display backlighting, enabling it to be used in dark places with no lighting. The backlighting

is switched off automatically after 1 minute to prolong battery life.
Pressing the 

button opens and allows to browse the configuration menu. On exiting the menu page, it returns to the measurement display.

Pressing the 

● 

button from the measurement screen shows the status of the device’s internal battery. To go back to the measurement screen,

press the 

● 

button again.

96

1

5

5

29

Battery

Menu

Light

Cod. 

130

010

IP 44

Battery

Menu

Light

Cod. 

130

010

IP 44

➂ ➃

Summary of Contents for GE 130 Series

Page 1: ...luido circolante Lo strumento di misura possiede le informazioni relative alla superficie di passaggio del fluido e i fattori di conversione in tale modo possibile ricavare il valore della portata ist...

Page 2: ...doneo all utilizzo con sostanze potenzialmente pericolose per l uomo come acidi liquidi fortemente basici liquidi infiammabili tossici o esplosivi Utilizzare esclusivamente sensori Caleffi approvati N...

Page 3: ...modo corretto e la portata indicata 0 Il Display LCD permette di visualizzare la portata durante la misura i men di configurazione e le altre informazioni necessarie per il corretto utilizzo dello str...

Page 4: ...ento divenga corretta MENU UNITA UNIT MENU LIQUIDO LIQUID MENU VERSION MODALIT DI MISURA UNITA UNIT l h UNITA UNIT l min UNITA UNIT GPM UNITA UNIT EXIT LIQUIDO LIQUID Acqua Water LIQUIDO LIQUID G30 LI...

Page 5: ...o se la valvola risulta correttamente chiusa 3 Inserire il tappo porta sensore l anello di blocco e il fermo verificandone il corretto posizionamento in caso di montaggio orizzontale della valvola uti...

Page 6: ...ianto Tipo Potenza Dati Portata impianto Temperature estive Temperature invernali Fluido Portata circuito 1 Portata circuito 2 Portata circuito 3 Dati Portata circuito 4 collettore Portata circuito 5...

Page 7: ...measured The flow meter contains data regarding the flowing surface of the medium and conversion factors needed to be able to calculate the instantaneous flow rate The device has an easy grip and non...

Page 8: ...d be hazardous to humans such as acids highly basic liquids and toxic flammable or explosive liquids Only use Caleffi approved sensors Do not open the flow meter or sensor if tampered with the warrant...

Page 9: ...than 300 l h if the sensor is not connected or inserted properly the device will not be able to measure correctly and a flow rate of 0 will be shown The LCD display shows flow rate during measurement...

Page 10: ...seconds for the reading to be corrected MENU UNIT MENU LIQUID MENU VERSION MEASUREMENT MODE UNIT l h UNIT l min UNIT GPM UNIT EXIT LIQUID Water LIQUID G30 LIQUID G50 LIQUID EXIT CALEFFI S p A I 001 CA...

Page 11: ...cap if the valve is shut properly 3 Insert the sensor holder cap the ring and lock checking the position of each if the valve is mounted horizontally use the discharge screw on the back to help inser...

Page 12: ...tem Type Power System Flow rate data Summer temperatures Winter temperatures Medium Circuit 1 flow rate Circuit 2 flow rate Circuit 3 flow rate Manifold Circuit 4 flow rate data Circuit 5 flow rate Ci...

Page 13: ...des Mediums bestimmt werden kann Das Messger t verf gt ber die Informationen zur Str mungsfl che des Messmediums und den Konversionsfaktoren Dadurch l sst sich der momentane Durchflusswert ermitteln D...

Page 14: ...bzw andere Fl ssigkeiten tauchen Die Sonde ist nicht f r den Einsatz mit potenziell f r den Menschen gef hrlichen Stoffen wie S uren stark basischen Fl ssigkeiten entz ndlichen gesundheitssch dlichen...

Page 15: ...ne vorschriftsm ige Messung ausf hren und am Display wird der Durchfluss 0 angezeigt Am LCD Display werden die Durchflussmenge beim Messvorgang die Konfigurationsmen s und die anderen Informationen f...

Page 16: ...einige Sekunden auf die Aktualisierung der Ger teanzeige warten MENU UNITA UNIT MENU LIQUIDO LIQUID MENU VERSION MESS MODUS UNITA UNIT l h UNITA UNIT l min UNITA UNIT GPM UNITA UNIT EXIT LIQUIDO LIQU...

Page 17: ...ndenverschluss den Ring und die Sicherung vorschriftsm ig einsetzen bei horizontaler Installation des Ventils die entsprechende Schraube auf der R ckseite als Einbauhilfe des Sondenverschlusses benutz...

Page 18: ...Typ Leistung Anlagen Durchfluss Daten Sommertemperaturen Wintertemperaturen Fl ssigmedium Durchfluss Kreis 1 Durchfluss Kreis 2 Durchfluss Kreis 3 Verteiler Durchfluss Kreis 4 Daten Durchfluss Kreis 5...

Reviews: