2.2.2
ASN-Gateway Mode Quick Start
Follow this instructions in this section if the Base Station is in an ASN Gateway topology.
NOTE: All the parameters available in this pane, are also available in other panes corresponding
to their parameter groups.
The Quick Start pane provides the basic parameters required for setting up the Base Station.
These include the unit and ASN Gateway address, frequency, bandwidth, etc.
These parameters require re-starting the service (*) or rebooting the Base Station (!) as
indicated. (See section 2.3.3). The necessary operation buttons are provided in the pane.
To set up the unit via the Quick Start pane
1. Click
the
Quick Start
menu option. The
Quick Start
pane appears.
Basic communication
parameters
(Corresponding to mode:
Standalone/ASN-GW)
Control options
The following operation buttons are available:
•
Apply
– implements changes performed by the user.
•
Reboot
– reboot device and load SW from Preliminary bank
•
Stop Service
/
Start Service
– two buttons used when service restart is required.
2. Update the required parameters in the Pane:
•
Base Station IP Address, Subnet Mask and Default GW (requires reboot).
•
ASN Gateway IP Address (requires reboot)
•
Base Station Center Frequency (requires service restart)
•
Base Station Bandwidth – Values: 3.5MHz, 5MHz, 7MHz, 10MHz. (requires service
restart)
•
Authentication
Mode:
© CalAmp Sentry 4G-900 Pico Base Station
5